Manual for PCS100 UPS-I

Manual for PCS100 UPS-I

Brand: ABB

Category: Power Supplies

Document Type: Manual

Language: EN

Available Languages: EN , ES

Uploaded: April 20, 2026, 7:58 p.m.

Manual Publish Date: 2022-03-31

Warranty Information

No specific warranty period is mentioned in the provided pages.

About This Document

This manual contains information regarding: - the general functions of the PCS100 UPS-I - the component enclosures making up the PCS100 UPS-I - operation of the PCS100 UPS-I - the user interface (GDM) - control and adjustments of the PCS100 UPS-I

Usage

This manual should be used during operation and adjustment of the PCS100 UPS-I. It should be referenced for: - commissioning the PCS100 UPS-I - servicing - operation and adjustment of the PCS100 UPS-I

Who Should Read This Manual?

This manual is intended for: - installation personnel - service personnel - maintenance personnel - operators

Prerequisites

An installation/repair/operator person working with the PCS100 UPS-I must: - be trained by ABB and have electrical operational and safety knowledge - have sufficient training to operate in an accidental touch safe service environment

Troubleshooting and error codes

Term Description
CB Circuit Breaker
CESE Ultracapacitor Energy Storage Enclosure
CGI Common Gateway Interface. CGI software is used when passing data between the Vcan serial communications bus and the remote web pages.
CT Current Transformer (sometimes means Coupling Transformer).
DSPE Digital signal processing engine. Control processor board. Fits on top of the MSIB and VSIB
GDM Graphic Display Module. The main HMI (Human Machine Interface) for the PCS100 products
GDMIB Graphics Display Module Interface Board. A small circuit board inside the GDM. Its main function is an interface between Vcan and the GDM.
MSIB Master Stack Interface Board (located in the master module)
NC Normally closed (Relay)
NO Normally open (Relay)
PCB Printed Circuit board
PCS100 A generic range of ABB LV power converter products.
PTC Positive Temperature Coefficient temperature sensor.
SCM System Configuration Module. A small circuit board located inside the master module. When the PCS100 product powers up the SCM checks the SW revisions and the hardware configuration (i.e., the number of inverter and rectifier modules).
VCAN The name of the high-speed serial communications bus protocol used by the different modules in the PCS100 products to communicate to each other. These modules are the Master Module, Inverter Module, Rectifier Module, SCM and GDM.
Vcanserver The name of the driver software for the Vcan bus
VSIB Slave Stack Interface Board (located in a inverter or rectifier module)
VT Voltage Transformer or potential transformers (PT) for metering and protection in high/medium-voltage circuits