Manual for R360 F2

Manual for R360 F2

Brand: Acer

Category: Server

Document Type: Manual

Language: EN

Available Languages: EN , ES

Uploaded: April 20, 2026, 8:02 p.m.

Manual Publish Date: 2013-05-01

Warranty Information

Warranty information is not explicitly detailed in the provided sections.

The Acer Altos R360 F2 FAQ provides detailed information on various aspects of the server, including its BIOS features, BMC capabilities, CPU specifications, expansion slots, iSCSI support, chassis details, and virtualization options. It covers system status LEDs, troubleshooting common issues, and video controller information. The FAQ aims to answer frequently asked questions to assist users in managing and operating the server effectively.

Troubleshooting and error codes

Issue Description
32-bit Red Hat Enterprise Linux 6 on 3 TB RAID volume shows only 2.2 TB available. This is due to the 1st RAID volume being more than 2TB, which is a limitation of 32-bit Red Hat Enterprise Linux 6. Create the 1st RAID volume less than 2TB. 64-bit Red Hat Enterprise Linux 6 in EFI mode supports RAID volumes more than 2TB.
Windows Server 2008 R2 installed in EFI mode or Legacy mode. Check the partition type with Disk Manager. The EFI System Partition indicates EFI mode. Alternatively, use the diskpart command in Windows command line.
SuSE Linux Enterprise Server installed in EFI mode or Legacy mode. Check the partition type with "df -a" command. The EFI partition indicates EFI mode.
Red Hat Enterprise Linux 6 installed in EFI mode or Legacy mode. Run the Disk Utility. The Partition Type indicates the installation mode. (See provided examples for EFI and Legacy modes).
System Status LED turns amber or blinks. Check the SEL (System Event Log) with Smart Console to identify the error cause. The LED will return to normal (Off) only when the error is fixed. Clearing the event log does not resolve the LED status.