Installation Guide for BS 35 / 45 / 60

Installation Guide for BS 35 / 45 / 60

Brand: AEG

Category: Heating

Document Type: Installation Guide

Language: EN

Uploaded: April 20, 2026, 8 p.m.

Warranty Information

For guarantees, refer to the respective terms and conditions of supply for your country.

Basic Operation

The AEG BS instantaneous water heater is electronically controlled and designed for heating shower water. The unit activates when water flow reaches 1.5-2 l/min, indicated by the "Power" light (A). The temperature is adjusted using the rotary control (B). Turning this control left allows for a cold shower without heating. An overheating protection device is included to cut off power if the unit gets too hot.

Troubleshooting and error codes

Fault Cause Solution
No hot water despite flow volume setting at right-hand stop. The water flow volume required for the unit to turn on has not been reached.
- The shower head is blocked with dirt or limescale.
- Flow volume too low
- Clean shower head
- Increase flow volume.
The unit is not working.
Electricity supply and flow available.
The water flow volume required for the unit to turn on has not been reached.
- Filter in the cold water connection pipe blocked with dirt.
- Water pressure not enough
Clean the filter after shutting off the cold water intake
- Increase mains pressure
"ELSD" Light on - The safety device activated. - Press "Reset" button