SWITCHING ON

To switch on the appliance do these steps:
  1. Connect the mains plug to the power socket.
  2. Press the ON/OFF button if the display is off.

SWITCHING OFF

To switch off the appliance do these steps:
  1. Press the ON/OFF button for 5 seconds.
  2. The display switches off.
  3. To disconnect the appliance from the power disconnect the mains plug from the power socket.

TEMPERATURE REGULATION

The set temperature of the wine cellar may be adjusted by pressing the temperature regulators. The temperature indicators show the set temperature. The set temperature will be reached within 24 hours. Refer to "Daily use - Wine Arrangement". ! After a power failure the set temperature remains stored.

LIGHT BUTTON

If you want to maintain the light on with the door closed, it is sufficient to open and close the door and the light will remain ON automatically for 10 minutes. If you want to switch off the light before the automatic turn off time, open the door and press the light button. The light has no negative effect on the quality on the wine.

DOOR OPEN ALARM

An acoustic alarm will sound if the door is left open for a few minutes. The door open alarm conditions are indicated by:
  • flashing Alarm indicator
  • acoustic buzzer
When normal conditions are restored (door closed), the alarm will stop. During the alarm, the buzzer can be switched off by pressing any button.

Troubleshooting and error codes

Problem Possible cause Solution
The appliance does not operate. The lamp does not operate. The appliance is switched off. Switch on the appliance.
The mains plug is not connected to the mains socket correctly. Connect the mains plug to the mains socket correctly.
The appliance has no power. There is no voltage in the mains socket. Connect a different electrical appliance to the mains socket. Contact a qualified electrician.
The lamp does not work. The lamp is in stand-by. Close and open the door.
The lamp is defective. Refer to "Replacing the lamp".
The compressor operates continually. The temperature is not set correctly. Set a higher temperature.
The door is not closed correctly. Refer to "Closing the door".
The door has been opened too frequently. Do not keep the door open longer than necessary.
The product temperature is too high. Let the product temperature decrease to room temperature before storage.
The room temperature is too high. Decrease the room temperature.
Water flows on the rear plate of the appliance. During the automatic defrosting process, frost defrosts on the rear plate. This is correct.
Water flows into the appliance. The water outlet is clogged. Clean the water outlet.
Products prevent that water flows into the water collector. Make sure that products do not touch the rear plate.
Water flows on the ground. The melting water outlet does not flow in the evaporative tray above the compressor. Attach the melting water outlet to the evaporative tray.
The temperature in the appliance is too low. The temperature regulator is not set correctly. Set a higher temperature.
The temperature in the appliance is too high. The temperature regulator is not set correctly. Set a lower temperature.
The door is not closed correctly. Refer to "Closing the door".
Many bottles are stored at the same time. Store less bottles at the same time.
There is no cold air circulation in the appliance. Make sure that there is cold air circulation in the appliance.
dEMo appears on the Display. The appliance is in demonstration mode (dEMo) Keep pressed approximately 10sec the Alarm button since a long sound of buzzer is heard and the Display shut off for a short while: appliance start works regularly.
Upper or lower square is shown in the temperature Display. An error has occurred in measuring the temperature. Call your service representative (the cooling system will continue to keep food products cold, but temperature adjustment will not be possible).