Manual for WSP 2010

Manual for WSP 2010

Brand: AEG

Category: Heating

Document Type: Manual

Language: EN

Uploaded: April 20, 2026, 7:55 p.m.

Warranty Information

For guarantee, please refer to the respective terms and conditions of supply for your country.

1. Operating Instructions

1.1 Technical Description

Storage heaters store electrically generated heat during low-cost electricity tariff periods (depending on the electricity supply company, mainly during the night hours). This is then discharged according to the desired room temperature as hot air by a fan and to a small extent through the surface of the heater.

1.2 Operation

The unit is operated by the control panel (1) on the right side wall (fig. 1).

1.2.1 Heat Storage

The degree of heat storage (charging) is determined by the selector knob (fig. 17). - No charging: Setting is "". - Transitional period (Spring/Autumn): Setting is "1", corresponds to about 1/3 full charge. - Mild Winter days: Setting is "2", corresponds to about 2/3 full charge. - Winter days: Setting is "3", corresponds to full charge.

1.2.2 Heat Discharge

The heat discharge is controlled by a wall-mounted or integrated AEG room temperature regulator (special accessory). Set the desired room temperature at the regulator, which will then automatically control the heat discharge with the fan to maintain the set temperature. On very cold days, it's advisable to leave the room temperature regulator on during absences to keep the temperature around 10 °C for frost protection.

Troubleshooting and error codes

What to do when...? For the User For the specialist
• the storage heater does not get hot Check whether...
- the selector knob is set to position 3.
- the corresponding fuses in your fuse box are defective or the Fl switch has switched off. Eliminate the cause!
Check whether...
- the control of the heating element contactor is OK.
- there is a voltage at terminals L1/L2/L3.
- whether the safety temperature limiter (F1) has triggered.
If the following day the storage heaters have still not heated up, call a specialist.
• the storage heater housing should get extraordinarily hot even in mild weather Check whether
- the fan can be switched on with the room temperature regulator.
If not, call a specialist.
- the fluff screen in the air inlet grille is blocked. Eliminate cause as described in section 1.4.1!
Check whether...
- the room temperature regulator has switched on and voltage is applied at terminal LE.
- the fans are turning.
- the safety temperature regulator (N5, see page 3, fig. 1) in the air outlet has switched off.
- the control signal Z1 of the charging control unit is applied at terminal A1/Z1 in the storage heater.