The 3300/25 Dual Accelerometer Input Monitor provides two independent channels for on-line machine monitoring using accelerometers. It offers programmable filtering (high-pass, low-pass, band-pass) for selected frequency components. The monitor features OK, Alert, and Danger status LEDs, along with bypass and alarm relays. Functions include Timed OK/Channel Defeat, Danger Bypass, First Out alarms, Trip Multiply, and multiple self-test modes (Cyclic, Power-up, User-invoked). It displays continuous acceleration or velocity measurements and provides buffered and recorder outputs. Error codes are displayed on the LCD.

Troubleshooting and error codes

Error Code Description Possible Cause Solution
E1 Monitor internal error Internal hardware fault Refer to Self Test and Error Codes sections.
E2 Invalid Configuration Incorrect jumper settings Verify jumper settings according to manual.
E3 Transducer Fault Open or shorted transducer Check transducer wiring and integrity.
E4 Low Input Signal Input signal below minimum threshold Verify transducer output and signal conditioning.
E5 High Input Signal Input signal above maximum threshold Check for excessive vibration or signal overload.