Warranty Information

This product comes with a limited warranty against manufacturer defects that result in leaks.

Operating Instructions

The Bestway Flowclear Sand Filter is designed for use with storable pools only. Ensure the filter is placed on a solid, level surface at least 2 meters away from the pool edge. Connect the filter to the pool's inlet and outlet using the provided hoses and ensuring all connections are secure. Before first use, perform backwash and rinse cycles to clean the sand bed. To operate, set the control valve to 'Filter' and plug in the pump. Monitor the pressure gauge; when it reaches 0.021MPa (3PSI) or higher, or water flow is reduced, it's time to clean the sand by performing backwash and rinse cycles again. Regular maintenance, including cleaning the strainer and winterizing the unit, is crucial for performance and longevity.

Troubleshooting and error codes

Problems Probable Causes Solutions
Sand is flowing to the pool - Sand is too small
- Move the control valve from the backwash to the filter function without stop the sand filter
- The level of the sand is too high
- The skimmer was broken
- Recommend 0.45mm to 0.85mm #20 silica sand
- Stop the sand filter every time set the control valve
- Check if the level of the sand is between the marked "MAX" and " MIN" on the collector hub
- Replace the skimmer
No water flow - Stopper plugs were not removed
- Air was not released
- The control valve was set to Closed
- The strainer was blocked
- Sand filter broken
- Remove the stopper plugs and insert the debris screens
- Release the air
- Set to filter function
- Clean the strainer
- Call for service
Excessive filter pressure - Dirty filter
- Calcified sand bed
- Insufficient backwashing
- The pressure gauge was broken
- Backwash
- Inspect sand and change if necessary
- Backwash until effluent runs clear
- Replace the pressure gauge
Control Valve leaks from the port D - Control Valve was set between two functions
- The gasket was broken
- Set to one function
- Replace the gasket
Connectors leaks - Washer of the connectors not in place
- Washer of the connectors broken
- O-ring on the hose connection was broken
- Loose Hoses
- Reposition the washer
- Replace the washer
- Replace the o-ring
- Tighten them