Brand: BOSCH
Category: Air Conditioner
Document Type: Manual
Language: EN
Brand: BOSCH
Category: Air Conditioner
Document Type: Manual
Language: EN
Uploaded: Nov. 21, 2025, 8:40 p.m.
Powering On/Off: Insert the plug and press the power button ($⌛$) to switch on. Press the same button to put the appliance on standby.
Modes: Select operating modes (Auto, Silent, Sleep, Air Conditioning, Dehumidification, Fan) using the mode selection button.
Temperature and Fan Speed: Adjust temperature using the Up/Down buttons. Select fan speed (Minimum, Medium, Maximum) using the fan speed selection button.
Swing Function: Activate to move the air outlet flap up and down for even air distribution.
Timer: Program delayed start-up or shut-down.
Remote Control: Use the remote control to operate all functions from a distance.
| Problem | Possible cause | Possible solution |
|---|---|---|
| The appliance does not turn on when pressing ON/OFF button. | The appliance is not plugged in. There is no current. |
Plug in the appliance. Check if a circuit breaker has flipped off and in case reset circuit breaker. Otherwise wait. |
| The appliance works for a short time only. | Room temperature is lower than the setting temperature. There are bends or kinks in the air exhaust hose. |
Reset the setting temperature. Position the air exhaust hose correctly, keep it as short as possible and free of bends. |
| The appliance turns on and off rapidly. | The air filter is soiled. | Turn off the appliance and clean the filter. |
| The appliance is working in air conditioning modes, but does not cool the room properly. | Unfavourable ambient conditions: windows, doors and/or curtains are open. Unfavourable ambient conditions: the room contains powerful heat sources. The air filter is soiled. Incorrect temperature setting. Compressor shut-off. |
Close doors, windows and curtains. Eliminate the heat sources. Turn off the appliance and clean the filter. Setting temperature should be lower than ambient temperature. Wait approximately 4 minutes and listen for compressor to restart when set in air conditioning mode. |
| Unpleasant odours during operation. | Air intakes and/or air outlets are obstructed. The technical specification of the appliance is not adequate for the room size in which it is located. Unpleasant odours in the air may enter the appliance and spread. The air filter is soiled. |
Check and remove any obstacles obstructing air in- or/and out takes. Reconfirm that the cooling capacity is adequate for the room in which it is located. Turn off the appliance and clean the filter. |
| Dust is being discharged from the air outlet. | Dust may accumulate in the appliance if it is shut down for an extended period and not covered. | N/A |
| The appliance is noisy and vibrates too much. | The ground is not level. The air filter is soiled. |
Place the appliance on a flat, level surface. Turn off the appliance and clean the filter. |
| The appliance is noisy. | In order for the appliance to work, the appliance produces some noises that are considered normal. At the top of the appliance, a sound of rushing air being moved by the fan can be heard. High efficient compressors may occur high-pitched sound during air conditioning operation. A gurgling or hissing noise is normal during operation. This is caused by the flow of refrigerant. |
N/A |
| The remote control does not turn on. | The batteries are empty. | Replace the batteries. |
| The appliance does not receive signal from the remote control. | The signal between the remote control and signal receiver is interrupted. | The remote control must be no more than 5 meters away from the appliance without obstacles between the remote control and the appliance. |
| The error messages FL, E2, E4, E6. E7 appear on the display. | The appliance has a self diagnosis system to identify a number of malfunctions. | → Chapter 8.1 "Self-diagnosis", Page 24 |