Warranty Information

All Braun Household products carry a minimum guarantee period of two years.

Using Your Braun CareStyle 3

Before First Use: Read instructions carefully. Clean all parts as instructed.

Filling the Water Tank: Ensure the appliance is off and unplugged. Remove or open the water tank, fill with tap water (do not exceed 'max' level). For hard water, use a 50/50 mix of tap and distilled water. Reinsert or close the tank. Place on a stable surface.

Starting Ironing: Place iron on rest, plug in, press On/Off. Iron heats up (temp. light on, On/Off LED flashing). Once heated, temp. light off, On/Off LED solid. Set temperature (1=synthetics, 2=wool/silk, 3=cotton/linen). For steam, set temp. between 2 and 'max', press steam button (14) or precision shot button (16). Adjust steam with regulator (6).

Precision Shot: Press button (16) fully for steam from the tip only.

Boiler Sleep Mode: Activates after 10 mins of no steam. Press steam button (14), reset (4), or precision shot (16) to restart.

After Ironing: Press On/Off (1) to turn off. Unplug, let cool. Empty water tank. Lock iron if applicable (12).

Descaling: After 15L water, LED (5) flashes. Switch off, unplug, cool (2.5h). Empty tank, remove iron, remove cover (9), unscrew valve (11). Empty boiler. Add 500ml tap water ONLY. Screw valve, shake, empty. Repeat. Plug in, switch on (1), press reset (4) for 5 secs.

Cleaning: Ensure appliance is off, unplugged, and cool. Wipe soleplate with damp/dry cloth. Never use abrasives or chemicals. Clean handle with damp cloth.

Troubleshooting and error codes

PROBLEM CAUSE REMEDY
The appliance does not switch on. The appliance is not plugged into a mains socket. Make sure the appliance is correctly connected and press the On/Off button.
Steam comes out under the base unit. The "max" pressure safety system has opened. Turn the appliance off immediately and contact an authorised Braun Customer Service.
There are some water drops from the holes in the bottom of the soleplate. Water has condensed inside the tubes because steam is being used for the first time, or has not been used for some time. Press the steam button several times away from the ironing board. This will eliminate cold water from the steam circuit.
Brown coloured fluid leaks from the soleplate. The temperature selector is not in the correct position. Set the temperature between temperature level 2 (• •) and "max" on the temperature selector.
The first time the appliance is turned on, you notice smoke / smell. Chemical water softeners, distilled water or additives have been poured into the water tank or boiler. Never pour products into the water tank. Clean the sole plate with a damp cloth and rinse the boiler.
The appliance emits an intermittent noise associated with vibrations. Some parts have been treated with sealer/lubricant which evaporates the first time the iron heats up. This is normal and will stop when you have used the iron a few times. If the smoke/smell is still present after turning off the appliance, contact an authorised Braun Customer Service.
The cleaning valve is difficult to unscrew. Water is being pumped into the boiler. The water tank is empty. This is normal and no action is needed. Refill the water tank and press the reset button.
All LEDs flashing. System error. Unplug the system, plug in again and press the On/ Off button. If this problem is still present, turn the appliance off immediately and contact an authorised Braun Customer Service.
Steam comes out from the cleaning valve. The cleaning valve is not tightened correctly. Turn off the appliance and tighten the cleaning valve correctly, but not overtighten it. Note: the cleaning valve might be hot.
Ironing system is ready, but no steam emission from the iron. The cleaning valve gasket is damaged. Turn off the appliance immediately and contact an authorised Braun Customer Service.
The LED is still on although water has been refilled. End of water alarm has been reset without water refill. Refill the water tank and press the steam button several times for 1 minute until the pump loads water inside the system.
The LED is still on although water has been refilled. The reset button has not been pressed or has not been pressed correctly. Turn off the appliance and wait until it has cooled down. Make sure the reset button is pressed correctly.