Braun offers a 2-year guarantee on the product from the date of purchase.
| Problem | Solution |
| Power bars do not light up when treatment window is placed on the skin. | Make sure the device is connected to an electrical outlet. Press the gentle mode button (4) to activate it. Ensure both skin tone sensors are in full contact with the skin. If needed, move the device in a way that both skin tone sensors get skin contact. |
| The device doesn't work on small areas. | Use the precision head* (11) on small, hard-to-reach areas (*if available). Make sure both skin tone sensors are in contact with the skin. |
| Flashing sequence slows down. | Device is in heat-protection mode. To get back to normal speed, allow device to cool down. |
| On the power bar, only the first LED illuminates red. | Invalid skin tone reading. Your skin is either too light or too dark. The device will not flash. |
| Gentle mode indicator is flashing. | Device is deactivated. Press the gentle mode button to re-activate it. |
| First LED on power bars flashes red. | Head (10 or 11) has been taken off. Re-attach it. |
| The power bars show an unfamiliar pattern of one red LED shining along with individual white LEDs. | Device error. Device will not operate. Unplug and reconnect. If error persists, contact a Braun Service Centre for repair. |
| All white LEDs flash. | End of product lifetime. Maximum number of flashes (300,000) has been reached. |
| The device is broken, cracked or appears defective. | Do not use if the handle, the base station or the main cord is damaged. If you are in any doubt about the safety or suspect it is damaged in any way, you must not use it. |