Warranty Summary
| Contents Code | Section Code | Fault Indication |
|---|---|---|
| 0 | A | **Activation of safety device Indoor (general)** |
| 1 | A | **Faulty PCB** |
| 2 | A | **Fan interlock (manual)** |
| 3 | A | **Adnormal drain water level or plug missing** |
| 4 | A | **Adnormal heat exchanger (1) temp.** |
| 5 | A | **Adnormal heat exchanger (2) temp.** |
| 6 | A | **Fan motor overload over-current lock** |
| 7 | A | **Air direction adjust motor lock** |
| 8 | A | **AC input over-current** |
| 9 | A | **Faulty electronic expansion valve** |
| A | A | **Heater overheating** |
| H | C | **Faulty sensor system (general)** |
| C | C | **Faulty drain water level** |
| J | C | **Faulty heat exchanger temp. sensor system (R2T)** |
| E | C | **Faulty gas pipe temp. sensor system (R3T)** |
| F | C | **Fan motor overload over-current, faulty lock sensor system** |
| 1 | C | **Air direction motor lock, faulty sensor system** |
| 2 | C | **Faulty AC input current sensor system** |
| 3 | C | **Faulty air suction temp. sensor system (R1T)** |
| F | E | **Activation of safety device outdoor (general)** |
| 1 | E | **Faulty PCB** |
| 2 | E | **Faulty air sensor system** |
| 3 | E | **Faulty power supply sensor system** |
| 4 | E | **Abnormal high pressure (HPS)** |
| 5 | E | **Abnormal low pressure (LPS)** |
| 6 | E | **Compressor motor overload** |
| 7 | E | **Compressor motor over-current lock** |
| 8 | E | **Out door fan motor overload** |
| 9 | E | **AC input over-current** |
| A | E | **Faulty electronic expansion valve** |
| H | E | **Pump over-current lock** |
| 1 | H | **Activation of safety device for system No. 1** |
| 2 | H | **Activation of safety device for system No. 2** |
| F | J | **Faulty refrigerant system (general)** |
| 1 | J | **Faulty current pressure sensor system** |
| 2 | J | **Faulty discharge pipe temp. sensor system** |
| 3 | J | **Faulty refrigerant pressure sensor system** |
| 4 | J | **Abnormal temp. sensor equivalent saturation temp. sensor system** |
| 5 | J | **Abnormal temp. rise inside control box** |
| 6 | J | **Abnormal temp. rise of radiation fin (power transistor)** |
| L | J | **Faulty INV system** |
| 1 | L | **Faulty PCB** |
| 2 | L | **Faulty temp. rise sensor inside control box** |
| 3 | L | **Faulty temp. rise of radiation fin (power radiation fin** |
| 4 | L | **Faulty DC current sensor system** |
| 5 | L | **Faulty AC or DC output current system** |
| 6 | L | **Air conditioner (multi) general** |
| 7 | L | **Inverter current abnormal** |
| 8 | L | **Inverter start-up error** |
| 9 | L | **Faulty power transistor** |
| P | L | **Gas shortage (ice thermal storage equipment)** |
| 1 | P | **High voltage of capacitor in inverter circuit or power imbalance** |
| 2 | P | **Short of gas** |
| 3 | P | **Reversed phase connection** |
| F | P | **Faulty power supply voltage (general) or check operation is not complete** |
| 1 | U | **Faulty transmission between indoor and outdoor units** |
| 2 | U | **Failure of transmission between outdoor units** |
| 3 | U | **Faulty transmission between remote controller** |
| 4 | U | **Faulty transmission between indoor units (main & sub)** |
| 5 | U | **Faulty transmission to/from remote controllers (main & sub)** |
| 6 | U | **Faulty transmission between indoor & outdoor in the same system** |
| 7 | U | **Im proper combination of unit address indoor & outdoor, indoor & outdoor unit address setting** |
| 8 | U | **Incorrect wiring/piping to/from peripheral equipment (air central control controller)** |
| 9 | U | **Faulty central control address setting (Address duplications)** |