Brand: DEA
Category: Gate Operators
Document Type: Manual
Language: EN
Available Languages: EN , ES
Uploaded: April 20, 2026, 8:08 p.m.
Manual Publish Date: 2012-03-13
The product comes with a 24-month warranty.
The NET24N is a universal control board for DEA System 24V motors, with or without encoder. It offers simple configuration for inputs and outputs, adapting to various automation types. Initial setup optimizes settings for the selected gate type. Standard programming follows for specific installation parameters.
If a configuration is already saved, the display will show "-ES-", "TYPE", "-00-", and the closed gate symbol.
| Mess. | Description | Possible Solutions |
|---|---|---|
| Err P | Setup error: Reset procedure not completed correctly. Control board awaits commands. | - Check for obstructions or excessive friction during motor operation. - Apply START impulse to initiate reset. - Check if maneuver was successful. If necessary, manually move gate wings. - Adjust motor/motor settings and force. |
| Err 3 | Photocells and/or safety devices activated or damaged. | Check the proper functioning of all safety devices and photocells. |
| Err 4 | Possible damage to the control board power circuit. | Disconnect and reconnect power. Apply START impulse; if error persists, replace control board. |
| Err 5 | Motor operation time exceeded: motor/motors exceeded maximum operating time (5 min) without stopping. | - Apply START impulse to initiate reset. - Check if maneuver was successful. |
| Err | Obstacle search time exceeded: With inactive anti-crushing sensor, an obstacle was detected that prevented wing movement for over 10 seconds. | - Check for obstructions or excessive friction during motor operation. - Apply START impulse to initiate reset. - Check if maneuver was successful. |
| Err None | Motor movement error. | - Ensure motors and encoder are correctly connected. - Check J5 and J9 jumper positions. - If error persists, replace control board. |