Manual Publish Date: 2022-11-01
| Issue | Corrective Action |
|---|---|
| BOSS-N1 supports only single drive RAID 0 | BOSS-N1 allows physical connections of two M.2 NVMe drives. However, only one M.2 NVMe drive is used to create RAID 0 volume and the other M.2 NVMe drive is not used. Expected behavior. No action is required. |
| Unwanted 0.0 MB unallocated space entry on BOSS-N1 | If no RAID is created on drives connected to BOSS-N1 controller, one unwanted entry of 0.0 MB unallocated space is displayed in the disk selection page during installation of the Windows operating system. Expected behavior. No action is required. |
| BOSS-N1 HII displays Maximum VD supported as 2 | BOSS-N1 HII displays Maximum VD supported as 2. Considering one functional VD and one foreign VD, HII displays Maximum VD supported as 2. Expected behavior. No action is required. |
| RAID level (between RAID 0 and RAID 1) migration is not supported on BOSS-N1 | BOSS-N1 allows physical connections of two M.2 NVMe drives. Either you can create single drive RAID 0 or two drive RAID 1. After this RAID operation, RAID level migration is not supported. Expected behavior. No action is required. |