| Error code | Fault condition | Check |
|---|---|---|
| E11 | Fill time too long. | Refer to test (1). |
| E13 | Water leak in tub or air leak in air bell. | Refer to test (2). |
| E21 | Water not pumping out fast enough. | Refer to test (3). |
| E23 | Drain pump relay on control board failed, wire off pump or pump defective. | Replace console control board, wire or pump. |
| E24 | Drain pump relay on control board failed. | Replace console control board. |
| E31 | Pressure sensor not communicating with control board. | Refer to test (4). |
| E35 | Pressure sensor indicates water overfill. | Refer to test (5). |
| E36 | Console control board problem. | Replace console control board. |
| E38 | Air chamber clogged or pressure sensor defective. | Check air chamber, rpl press. sensor. |
| E41 | Control board thinks the door switch is open. | Refer to test (6). |
| E43 | Console control board thinks the door locking device has failed. | Refer to test (7). |
| E44 | Console control board problem. | Replace console control board. |
| E45 | Console control board problem. | Replace console control board. |
| E46 | Console control board problem. | Replace console control board. |
| E47 | Console control board thinks the door PTC circuit is open in spin. | Refer to test (7). |
| E48 | Console control board thinks the door PTC circuit is closed. | Refer to test (7). |
| E52 | Bad signal from tacho generator. | Refer to test (8). |
| E56 | High motor current. | Refer to test (9). |
| E57 | High current on inverter. | Refer to test (9). |
| E58 | High current on motor phase. | Refer to test (9). |
| E59 | No tacho signal for 3 seconds. | Refer to test (10). |
| E5A | High temperature on heat sink caused by overloading. | Test first-if bad-rpl speed control brd. |
| E5B | High temperature on heat sink. | Replace speed control board. |
| E5C | High temperature on heat sink. | Replace speed control board. |
| E5D | Communication problem. | Refer to test (11). |
| E5E | Communication problem. | Refer to test (11). |
| E5F | Communication problem. | Refer to test (11). |
| E66 | Heating element relay failure. | Refer to test (14). |
| E67 | Input voltage on microprocessor incorrect. | Refer to test (15). |
| E68 | Current leakage to ground on heater or fuse opened. | Refer to test (14 & 15). |
| E71 | Wash NTC failure. | Refer to test (15). |
| E74 | Wash temperature does not increase. | Wire off NTC - rpl water valve. |
| E75 | Water temperature sensor circuit. | Refer to test (12). |
| E82 | Console control board problem. | Replace console control board. |
| E83 | Console control board problem. | Replace console control board. |
| E91 | Comunnication error between UI board and console control board. | Refer to test (16). |
| E93 | Console control board problem. | Replace console control board. |
| E94 | Console control board problem. | Replace console control board. |
| E95 | Communication error. | Replace console control board. |
| E97 | Console control board problem. | Replace console control board. |
| E98 | Console control board problem. | Replace console control board. |
| EB1 | Incoming power frequency out of limits. | Refer to test (13). |
| EB2 | Incoming line voltage above 130 VAC. | Check voltage at outlet. If < 130VAC, replace the console control board. |
| EB3 | Incoming line voltage below 90 VAC. | Check voltage at outlet. If > 90VAC, replace the console control board. |
| EBE | Console control board problem. | Replace console control board. |
| EBF | Console control board problem. | Replace console control board. |
| EF1 | Clogged drain pump. | Unclog the drain pump. |
| EF2 | Too much soap. | Advise customer to reduce the amount of soap they are using. |