This manual provides operating instructions for various Exacta washer extractor models. It covers program buttons, option buttons, start button functions, indicator lights, detergent container usage, display information, and error codes.
| Error code | Cause/Action |
|---|---|
| 01E | Acknowledgement signal for water level not received within time allowed. |
| 02E | Door status acknowledgement signal not received during program operation. |
| 03E | Door lock acknowledgement signal not received within time allowed. |
| 04E | Temperature sensing device indicates temperature below -5YC (continuity fault). |
| 05E | Temperature sensing indicates temperature above 98YC (short-circuit). |
| 06E | Water level above parameter set, on program start-up. |
| 07E | Water level above parameter set for safety, during program. |
| 08E | Increase in water temperature is below parameter set. |
| 10E | Water level is above parameter set (10 scale units) after water discharge. |
| 12E | The program control unit cannot read the program EPROM. |
| 13E | The program control unit receives no response from the motor control unit. |
| 14E | Water level system not calibrated. |
| 17E | Door status acknowledgement signal not received, although door lock acknowledgement signal has been received. |
| 18E | Only with CALCAD 4400. Start not allowed because full payment has not been made for that program, or the booking time is too short to allow completion of the wash program selected. |
| 19E | Communications between the CALCAD 4400 and the program control unit board interrupted. |
| 21E | The electronic timer wrongly configured. |
| 22E | The automatic calibration system for water level is not working. |
| 31E | Temperature of motor control unit heat sink too high. |
| 32E | Thermal protection for motor has cut out. |
| 33E | The motor control unit has received a start command from the program control unit without having the interlock signal. No fault in motor control unit interlock hardware. |
| 35E | Motor control unit indicating short-circuit between motor winding outputs. |
| 36E | Motor control unit indicating fault/error in receiving circuitry for lock acknowledgement signal. |
| 37E | Motor control unit indicating DC voltage level too low. |
| 38E | Motor control unit indicating DC voltage level too high. |
| 41E | The motor control indicates faults in the circuits for the motor's overheating protection. |
| 43E | The RDC card indicates that imbalance switches are activated when the motor is not turning. |
| 45E | The RDC card indicates that tacho pulses are absent at the requested motor speed. |