Manual for DUOX PLUS

Manual for DUOX PLUS

Brand: FERMAX

Category: Intercom System

Document Type: Manual

Language: EN

Available Languages: ES , EN

Uploaded: April 20, 2026, 7:52 p.m.

Warranty Information

The warranty is 24 months.

  • DUOX PLUS AMPLIFIER: Connection of modular buttons, keypad, display.
  • DL1 Mode LED: Indicates different operating modes such as Concierge, Inverse or Sequential Programming, and Standby/Night Concierge.
  • PRG. SW1: Programming button. Allows configuring the panel as MASTER for programming apartment terminals. Only one MASTER panel per installation.
  • Configuration - Amplifier Programming: Can function as a general entrance, block, or sub-block panel. Uses 6-digit addresses (BBSSNN) for apartments.
  • Panel Connectors: B,B (DUOX Bus), C/NO/NC (Dry relay contact), +12 (12Vdc output), BS (entrance push-button), SP (door sensor input).
  • CN2: Connection for individual buttons of Cityline continuous profile panels.
  • CN3: OneToOne Module connection.
  • Language Selector: Allows selecting the language for "door open" messages and voice-assisted configuration.
  • Audio Adjustment: Allows adjusting speaker and microphone volume.
  • SPK: Speaker connection.
  • JP1: Camera LEDs: Controls the camera's LED lighting.
  • JP2: Line adapter jumper: For type C line adaptation.
  • QR: QR Code: For accessing parameter configuration.
  • Programming data label: For recording the performed configuration.
  • Version: Indicates the amplifier version.
  • TECHNICAL CHARACTERISTICS: Includes IP/IK, power supply, consumption, illumination, audio power, volume, and operating temperature.
  • Default parameter values: Lists the default values for various parameters such as times, panel types, block/sub-block numbers, etc.
  • Capacities: Maximum number of push-buttons, calls from Keypad Panel, and number of panels.
  • RESTORE TO FACTORY VALUES: RESET: Functions to restore button mapping and parameters to factory settings.
  • PRE-WIRING: Wiring diagram and default button call assignment.
  • DUOX Amplifier Call: Use of combined push-buttons, apartment address coding, and making calls.

Troubleshooting and error codes

ProblemSolution
DL1 LED off.Check power supply.
Buttons not responding.Check MASTER configuration and CN1 connections.
No audio/video.Check BUS and SPK connections.
Door does not open.Check relay and door lock release connections.
No programming.Verify MASTER configuration.