Manual for Room Air Conditioner

Manual for Room Air Conditioner

Brand: FRIGIDAIRE

Category: Room Air Conditioner

Document Type: Manual

Language: EN

Uploaded: Nov. 21, 2025, 7:41 p.m.

Manual Publish Date: 2019-07-01

Warranty Information

Limited one-year warranty for functional repairs, covering parts and labor for defects.

The unit can be controlled via the touch pad or remote. Key operations include turning the unit On/Off, setting modes (Eco, Cool, Fan Only, Dry), adjusting temperature and fan speed, setting timers, activating sleep mode, and checking/resetting the dust filter indicator. The unit defaults to Eco mode upon startup, offering energy savings.

Troubleshooting and error codes

OCCURRENCE SOLUTION
Air conditioner will not operate. • Wall plug disconnected. Push plug firmly into wall outlet.
• Plug Current Device Tripped. Press the RESET button.
• House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
• Control is OFF. Turn Control ON and set to desired setting.
Air from unit does not feel cold enough. • Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above 60°F (16°C).
• Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.
• Reset to a lower temperature.
• Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode.
Air conditioner cooling, but room is too warm ice forming on cooling coil behind decorative front • Outdoor temperature below 60 F° (16°C). To defrost the coil, set FAN ONLY mode.
• Dust filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY mode.
• PureAir™™ filter(sold separately) may be dirty. Replace with new filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY mode.
• Temperature is set too low for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then, set temperature to a higher setting.
Air conditioner cooling, but room is too warm NO ice forming on cooling coil behind decorative front. • Dirty Dust filter - air restricted. Clean filters. Refer to Care and Cleaning section.
• PureAir™™ filter(sold separately) may be dirty. Replace with new filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY mode.
• Temperature is set too high. Set temperature to a lower setting.
• Air directional louvers positioned improperly. Position louvers for better air distribution.
• Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit.
• Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.
• Unit recently turned on in hot room. Allow additional time to remove "stored heat" from walls, ceiling, floor and furniture.
Air conditioner turns on and off rapidly. • Dirty Dust filter - air restricted. Clean filters. Refer to Care and Cleaning section.
• PureAir™™ filter(sold separately) may be dirty. Replace with new filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY mode.
• Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils more frequently.