| ERROR CODE | COMPONENT, SYSTEM, OR TEST | DESCRIPTION & CORRECTIVE ACTION |
|---|---|---|
| E00 | No error | There are no errors to display. |
| tS | Thermistor short | Thermistor voltage is over 4.8 VDC for more than 5 seconds. Check the PCB, wire, and thermistor. |
| t0 | Thermistor open | Thermistor voltage is under 0.2 VDC for more than 5 seconds. Check the PCB, wire, and thermistor. |
| dE | Door switch fail | Door interrupt voltage is continuously low level. Check the PCB. |
| od | Over dry | The time of dry process & cooling process is over 240 minutes. Check the PCB. |
| HE | Heating error | Heating temperature is over 75 degrees Celsius for more than 10 seconds. Check the PCB. |
| FE | Power frequency error | Power frequency is 50 Hz for more than 15 seconds. Check the power frequency and PCB. |
| bE2 | Button error | When the button is continuously pressed for more the 30 seconds. Check the button and PCB. |
| 3E1 | Motor relay open | When the motor should be running, the control detects the higher motor signal within the 60 seconds. Check the PCB, wire, and motor. |
| 3E2 | Motor relay stuck | When the motor state is stop, the control detects the zero cross motor signal within the 60 seconds. Check the PCB, wire, and motor. |