Parts/Service for JVM1750

Parts/Service for JVM1750

Brand: GE

Category: Microwave Oven

Document Type: Parts/Service

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 7:27 p.m.

Manual Publish Date: 2009-09-01

Warranty Information

GE will replace any part of the microwave oven that fails due to defects in materials or workmanship within one year of the original purchase date, including labor and related service.

Features and Benefits:

  • Sensor Cook: Automatically adjusts cooking time based on food type and amount.
  • Auto and Time Defrost: Provides automatic or user-specified defrosting times and power levels.
  • Turntable On/Off: Allows for even cooking or disables the turntable for larger dishes.
  • Removable Two-Position Oven Rack: Offers flexibility for cooking multiple items simultaneously.

Control Features:

The appliance features a door handle, door latches, a window with a metal shield for viewing, a shelf for multiple food items, a touch control panel for setting the clock and calendar, a cooktop light, and a grease filter.

The removable turntable and its support must be in place during operation. A convenience guide is also present.

Troubleshooting and error codes

JVM1750 Diagnosis Flow Chart
START - VERIFY MWO POWER CORD PLUGGED INTO OUTLET CHECK FUSE/CIRCUIT BREAKER - RESET BREAKER/REPLACE FUSE IF NEEDED
1. SET CLOCK (IF NEEDED) 2. PLACE CUP OF WATER AND NEON LIGHT TESTER IN UNIT 3. PROGRAM UNIT TO COOK NO YES
IS DISPLAY LIT? NO YES
VERIFY OUTLET VOLTAGE PRESENT UNPLUG & DISASSEMBLE
UNIT ABLE TO PROGRAM? YES NO
PERFORM KEY PANEL TEST
KEY PANEL OK? NO YES
REPLACE KEY PANEL REFER TO FRONT PAGE FOR MORE INFO
HVT IS GROUNDED YES NO
REPAIR / REPLACE A IS INTERNAL MWO 15A/20A FUSE OK?
SERVICE BREAKER TRIPS? IMMED AFTER A FEW SEC
MONITOR DOOR SWITCH OK? NO YES
INSTALL CLAMP ON AMMETER TO MWO'S INTERNAL FUSE LEAD ABOUT 5A < 2A
WATER HEATS / NEON TESTER LIGHTS? YES NO
MAGNETRON, BLOWER AND CAVITY LIGHT ON? CAVITY LIGHT ONLY ON MAGNETRON & HV COMPTS ARE GOOD
CHECK VOLTAGE ACROSS POWER RELAY ON PCB (DOOR CLOSED, NO COOKING PROGRAMMED) - SHOULD GET ABOUT 120V YES NO
CMO ONLY - IF AN OTR, GO TO "OTR START" BLOCK INSTALL CLAMP ON AMMETER TO A MAGNETRON LEAD < 1A > 8A
OTR START 1. UNPLUG UNIT 2. DISCHARGE HVC 3. SET DVM ON 2K OHM SCALE 4. MEASURE HVD SIDE OF HVC TO GROUND INFINITE (OPEN) SOME RESISTANCE
CHECK RESISTANCE OF SECONDARY SIDE OF HVT (SINGLE LEAD TO HVC) 70-150 OHMS OTHER
HVT IS OK YES NO
REPLACE MAGNETRON
REPAIR/REPLACE A CHECK RESISTANCE OF HVC - 2K OHM SCALE ON DVM
RESISTANCE < 2K OHMS? YES NO
HVC IS MISWIRED NO YES
REPAIR PLUG IN UNIT
IS DISPLAY LIT? YES NO
ANY SHORTED OR PINCHED WIRING? YES NO
REPAIR THEN GO TO A
REPLACE PRIMARY DOOR SWITCH A
REPLACE PCB B REPLACE HVT
CHECK TCO(s) OPEN CLOSED
CHECK WIRING TO HVT OK? YES NO
REPAIR A REPLACE TCO(s)
RETEST & REASSEMBLE - END
A B C
REPLACE PCB REPLACE HVT REPLACE PCB
D
1. SET CLOCK (IF NEEDED) 2. PLACE CUP OF WATER AND NEON LIGHT TESTER IN UNIT 3. PROGRAM UNIT TO COOK
LEGEND: A=REPAIR/REPLACE, B=REPLACE PCB, C=REPLACE HVT, D=TROUBLESHOOTING STEPS