One-year limited warranty for manufacturing defects, with an additional four-year limited warranty specifically for the magnetron tube.
| Issue | Potential Causes | Solution |
|---|---|---|
| Display is blank | No power, fuse blown, faulty control board/key panel | Check power supply, fuse, CVTY TCO, MGT TCO, Control XFMR. Verify control terminals. Replace PCB or Key Panel. |
| Some keys not working, erratic display, no beep, display goes blank, cannot clear display | Faulty control board/key panel | Perform Key Panel Test. Replace PCB or Key Panel. |
| Microwave cook does not start without touching start key | Faulty PCB or Key Panel | Press Start key. If problem persists, replace PCB or Key Panel. |
| Oven lamp & blower "on" and stays "on" | Faulty Relay 2 | Check Relay 2. Replace PCB if necessary. |
| Convection cook, speed cook, or microwave cook does not start | Faulty PCB or Key Panel | Perform Key Panel Test. Replace PCB or Key Panel. |
| Heaters, convection fan, and microwave do not come on | Faulty control board, faulty power supply, faulty magnetron/capacitor | Check power, wiring, TCOs, diode, magnetron, capacitor. Replace faulty components. |
| Power not coming on (upper, bottom, convection, microwave) | Faulty PCB, faulty power supply, faulty relays | Check power supply, relays, magnetron. Replace PCB. |
| Display counts down, but no heat | Faulty control board, faulty power transformer | Check power transformer winding resistance. Replace PCB. |
| Heater cycling issues | Faulty control board, faulty heaters, faulty TCOs | Check heater wiring, TCOs, filament. Replace faulty components. |
| Magnetron issues (no heat, filament not glowing) | Faulty magnetron, capacitor, fuse, wiring | Check magnetron filament, F to FA open/shorted, F to ground/FA to ground. Check capacitor. Replace magnetron or capacitor. |
| Service mode complete message | Normal operation after diagnostics | Follow prompts to exit service mode. |