Use the blower tube assembly to pile up dry leaves for collection or to blow them out of hard-to-reach areas. Ensure the product is fully assembled and the battery is installed. Hold the product by the main handle, keep the air vents clear, and direct the air stream away from yourself. Avoid blowing heavy objects.
Attach the vacuum tube assembly and collection bag. Hold the product by both handles, guide the nozzle along the ground, and ensure the volume of leaves is not too large to avoid clogging. Switch off and remove the battery if the product stops suddenly.
Switch off, remove the battery, and let the product cool down. Check, clean, and store the product.
| Problem | Possible cause | Solution |
|---|---|---|
| 1. Product does not start | 1.1. Battery pack is not properly attached | 1.1. Attach properly |
| 1.2. Battery pack is discharged | 1.2. Remove and charge battery pack | |
| 1.3. Battery pack is damaged | 1.3. Check by a specialist electrician | |
| 1.4. Snap-in button (12) with built-in switch is not secured | 1.4. Refit the snap-in button (12) to activate the built-in switch | |
| 1.5. Other electrical defect to the product | 1.5. Check by a specialist electrician | |
| 2. Product does not reach full power | 2.1. Battery pack capacity is too low | 2.1. Charge battery pack |
| 2.2. Air vents are blocked | 2.2. Clean the air vents | |
| 2.3. Collection bag is full | 2.3. Empty collection bag | |
| 3. Unsatisfactory blowing result | 3.1. Nozzle not properly assembled | 3.1. Refer to chapter "Blower / Vacuum tube assembly" |
| 4. Product suddenly stops | 4.1. Battery pack is discharged | 4.1. Remove and charge battery pack |
| 4.2. Battery pack is too hot | 4.2. Remove battery pack and let it cool down | |
| 5. Excessive vibration or noise | 5.1. Nozzle not properly assembled | 5.1. Refer to chapter "Blower / Vacuum tube assembly" |
| 5.2. Screws are loosen | 5.2. Tighten screws |