Manual for MSL3040

Manual for MSL3040

Brand: Hewlett Packard Enterprise

Category: Storage

Document Type: Manual

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 8:39 p.m.

Manual Publish Date: 2018-02-01

Warranty Information

Refer to the express warranty statements accompanying the product and services.

The HPE StoreEver MSL3040 Tape Library is a compact solution for unattended data backup. It houses tape cartridges in 3U modules with mailslots for easy access. The library is expandable with expansion modules and tape drives. Installations begin with a 3U base module, expandable with up to six 3U expansion modules. It is compatible with most operating systems, but requires direct OS or backup application support. Verify compatibility at http://hpe.com/storage/DAPRcompatibility.

Troubleshooting and error codes

Event code Message and description Details and solution
4124 Drive or media statistics could not be retrieved when unloading the tape. 1. Check the event log for additional events that provide more specific information.
2. If media-related tape alert events are reported, replace the media.
4125 Potential conflict: Tape drive has been accessed by multiple initiators. 1. View the list of host WWNN addresses listed in the event text.
• If only one host can have access the tape drive, ensure that the other hosts are not allowed to access the tape drive.
• If multiple hosts will access the tape drive, disable multi-initiator SCSI detection for the partition with the drive.
2. Close the event and continue normal use of the tape drive.
Table 19: Configuration change events
8000 The configuration of a drive changed.
8001 The drive was added or removed from the system.
8002 A partition was added/removed or changed.
8003 A mailslot bank was enabled/disabled.
8004 Drive firmware changed due to firmware upgrade.
8005 The configuration of hostname/domain name has changed.
8006 The email configuration settings have been changed.
8007 The configuration of a date/time format changed.
8008 The system language setting changed.