Manual for YUTAKI SERIES

Manual for YUTAKI SERIES

Brand: HITACHI

Category: Air Conditioner

Document Type: Manual

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 9:24 p.m.

Manual Publish Date: 2016-04-01

Warranty Information

No warranty information is available in the provided document.

YUTAKI units produce heating and domestic hot water, transforming renewable energy from the outside air into heat. They extract free energy from the air, enough to heat a home even on the coldest winter day. Every kW of electricity used can yield up to more than 5 kW of energy for heating, providing savings of up to 80% compared to traditional fossil fuel boilers. The new YUTAKI series offers outstanding performance in space heating and domestic hot water production. Cooling operation is also possible with a dedicated accessory. The system is controlled by a new user controller (PC-ARFHE) with enhanced functions.

The YUTAKI system can be configured for:

  • Space heating: Mono-valent, Mono-energy, or Alternating Bi-valent systems.
  • Domestic hot water production: Achieved using a domestic hot water tank.
  • Space cooling: Possible with a dedicated "Cooling kit" accessory.
  • Combination with solar panels: To heat DHW using solar energy.
  • Swimming pool water heating: To heat pool water between 24 and 33°C.

Troubleshooting and error codes

Alarm Code Retry Stop Code Yutaki S/SC Yutaki S80 Yutaki M Origin Detail of Abnormality Main Factors
3 - 0 0 0 Communication Transmission Alarm (Not outdoor unit detected) Loose, disconnected, broken or short-circuited connector
11 - 0 0 0 Indoor Water inlet thermistor abnormally (THMwi) Loose, disconnected, broken or short-circuited connector
12 - 0 0 0 Indoor Water outlet thermistor abnormally (THMwo) Loose, disconnected, broken or short-circuited connector
13 - 0 0 0 Indoor Indoor Liquid Pipe Temp Thermistor Abnormality (THMI) Loose, disconnected, broken or short-circuited connector
14 - 0 0 0 Indoor Indoor Gas Pipe Temperature Thermistor Abnormality (THMg) Loose, disconnected, broken or short-circuited connector
15 - (0) (0) (0) Indoor Water Circuit 2 thermistor abnormally (THMwo2) Loose, disconnected, broken or short-circuited connector
16 - (0) (0) (0) Indoor Water DHW thermistor abnormally (THMdhwt) Loose, disconnected, broken or short-circuited connector
17 - (0) (0) (0) Indoor Auxiliary sensor 2 thermistor abnormally (THMaux2) Loose, disconnected, broken or short-circuited connector
18 - (0) (0) (0) Indoor Auxiliary sensor 1 thermistor abnormally (THMaux1) Loose, disconnected, broken or short-circuited connector
19 - 0 - - Indoor Water Plate HEX pipe thermistor abnormally (THMwohp) Loose, disconnected, broken or short-circuited connector
23 - 0 - - Indoor Suction R134a pipe thermistor abnormally (THMs) Loose, disconnected, broken or short-circuited connector
25 - (0) (0) (0) Indoor Discharge R134a pipe thermistor abnormally (THMd) Loose, disconnected, broken or short-circuited connector
40 - 0 0 0 Indoor Incorrect LCD setting Current LCD configuration does not allow proper operation
63 - (0) (0) (0) Communication Transmission error between Central and indoor communication Indoor fuse meltdown, Indoor/ central connection wiring (breaking, wiring error, etc.)
70 P70 0 0 0 Indoor Hydraulic alarm flow & Water Pump malfunction Water flow is not detected in the hydraulic cycle or Pump defective
83 P83 0 0 0 Indoor Hydraulic alarm pressure Water pressure is not detected in the hydraulic cycle
72 - 0 - - Indoor Thermostat Heater Alarm High temperature is detected in Electric Heater
73 - 0 0 0 Indoor Mixing over-temperature limit protection for Mixed circuit. Circuit 2 supply temperature > Target temperature + offset
74 P74 0 0 0 Indoor Unit over-temperature limit protection Two > Tmax +5K