  1. Set Film Speed: Lift and rotate the shutter speed dial's outer ring to match the film's ASA number to the red index. Cock the rapid wind lever.
  2. Set Shutter Speed: Turn the shutter speed dial to the desired speed. Use 1/125s or faster outdoors, 1/30s or similar indoors.
  3. Compose and Focus: View through the viewfinder and turn the distance scale ring until the subject is sharp at the microprism center.
  4. Turn on Light Meter: Push the switch button; a red window indicates it's on. Observe the needle in the viewfinder. Turn off when not reading.
  5. Rotate Diaphragm Ring: Adjust the diaphragm ring until the meter needle centers for correct exposure. Adjust shutter speed if centering is not possible.
  6. Release Shutter: Hold the camera firmly and trip the shutter. The meter turns off, and the diaphragm reopens. Cock the lever for the next shot.

Troubleshooting and error codes

Lens element scratches Mounting lens without rear mount cap Always use the rear mount cap when removing the lens.
Damaged diaphragm release pin Mounting lens with meter switched on Switch the meter off before mounting the lens.
Battery drains quickly Leaving meter switched on Always switch the meter off when not in use.
Shutter speed/film speed settings off meter's range Red index on shutter speed dial Change shutter speed to a faster or slower setting.