Manual for MN10CES

Manual for MN10CES

Brand: Honeywell

Category: Other

Document Type: Manual

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 8 p.m.

Manual Publish Date: 2013-11-01

Warranty Information

5-year limited warranty covering parts and labor, with extended coverage for sealed system components.

Cooling and Dehumidifying Operation: Keep doors and windows closed for optimal efficiency. Fan Operation: An open window can improve air circulation. Before Installation: Place the unit UPRIGHT for 20 minutes to allow refrigerant to stabilize. Power Control: Turns the unit on and off. Mode Control: Choose from Cool, Dehumidify, and Fan. In Cooling Mode, adjust fan speed and temperature (61°F - 89°F). In Dehumidifying Mode, if room temperature is above 77°F, fan speed can be adjusted; otherwise, it's preset to LOW. For efficiency, do not connect the exhaust hose and allow warm air to return to the room. Continuous drainage is recommended. In Fan Mode, air circulates without cooling. Fan Speed Control: High, Medium, Low. Timer Control: Set auto turn-off (while running) or auto turn-on (while in standby) from 1-24 hours. Temperature/Timer Set Controls: Adjust timer and thermostat. Default display is room temperature. Temperature adjustable only in cool mode. Note: Pressing both "<" and ">" buttons simultaneously toggles between Celsius and Fahrenheit. Warning Light: Flashes if the internal water tank is full, preventing operation until drained. Important: Wait 3 minutes before switching the unit back on after turning it off. Remote Control: Functions mirror the touch screen panel. Do not place in direct sunlight. Battery Installation: Use 2 AAA batteries, noting polarity. Remove batteries if not in use for over a month.

Troubleshooting and error codes

Problem Possible Cause Solution
The air conditioning unit does not start • No electricity.
• Batteries in the remote control need to be replaced.
• The power cord is not properly plugged in.
• The safety GFI plug has tripped.
• Check for power.
• Change remote control batteries.
• Remove and reconnect the power cord.
• Reset the safety GFI plug; if problem persists contact customer support.
Runs a short while only • The thermostat temperature setting is too close to room temperature.
• Air outlet is blocked.
• There are tight bends in the air exhaust hose.
• Lower the set temperature.
• Make sure the exhaust hose is properly connected.
• Connect exhaust hose as per instructions on page 9.
Runs but no cooling • A door or window is open.
• The air filter is dirty.
• The exhaust hose is detached.
• Temperature setting is too high.
• Air outlet or intake is blocked.
• Make sure the window or door is closed.
• Clean the air filter.
• Reinstall exhaust hose properly (refer to page 9, Installation)
• Reduce temperature setting on control panel.
• Remove blockage.
Will not run and water full indicator light is ON • Excess water condensation inside the tank. • Drain the water through the drain plug (refer to page 14, Water Condensation Drainage).