Installation Guide for RPLS730B / RPLS731B

Installation Guide for RPLS730B / RPLS731B

Brand: Honeywell

Category: Other

Document Type: Installation Guide

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 6:19 p.m.

Manual Publish Date: 2013-01-01

Warranty Information

Honeywell warrants this product, excluding battery, for one (1) year from the date of purchase against defects in workmanship or materials.

Applications: Controls lighting and motors (resistive, inductive loads up to 2400W/20A@120V, motors up to 1 HP).

Installation: Ensure at least 2 white wires are present. Disconnect power, remove old switch, install new switch as per diagram, reconnect power.

Power-On: Pry open switch door, ensure ON/OFF selector is ON, reset with paper clip. Display may be dim initially; wait 2 minutes for battery charge.

Clock Setting: Switch between 12/24 hour format. Set time using HOUR/MIN buttons, day using DAY button.

Operating Modes: Manual (MAN) for direct control, Automatic (AUTO) for programmed schedules. Press door for 3 seconds to switch modes. Temporary override by brief press.

Troubleshooting and error codes

Problem Solution
Blank display Verify circuit breaker at main panel.
Ensure the ON/OFF selector is at ON.
Reset the switch using a paper clip.
Faded or irregular display Ambient temperature below freezing point.
Cannot switch between 24-hour format and 12-hour format First, press one of the control buttons so that MAN or AUTO appears on display.
Programs do not run as expected Make sure the switch is properly programmed.
Note that -:- - indicates an inactive program.
If the switch has been configured for 12-hour format, check that PM appears on the left side of the screen when an afternoon time is displayed.
The switch resets itself without apparent reason when used to control an inductive load such as a relay or a contactor. The reset is caused by the load. Install a snubber (AC130-03) at each relay/contactor.