The DT-6360STC is a dual-technology motion sensor (PIR and microwave) designed for ceiling mount applications. It offers various mounting options including surface and flush mounting. The unit features diagnostic LEDs for self-testing and status indication. Installation involves wiring the sensor, potentially adjusting PIR mirror assemblies for different ceiling heights, and configuring tamper switches for added security. System testing involves walk-testing the coverage area and adjusting microwave range as needed. The device also includes an INFORMER circuit to detect misapplication or malfunction, and an alarm sequence processing to determine valid alarms based on combined PIR and microwave events. Troubleshooting guides are provided for self-test errors and INFORMER circuit alerts.

Troubleshooting and error codes

TEST DESCRIPTION ALARM
(Red)
MW
(Yellow)
PIR
(Green)
ACTION
Power Up Self-Test No action required.
On Line - All Self-Tests Passed,
Ready for Walk-Test
Unit is working properly.
On-going Self-Test Send the unit in for repair.¹

¹ Return the DT-6360STC to Honeywell for repair.


Reaction of LEDs
to Walk-Test
Type of
Problem
Possible
Causes
Condition of LEDs
with No Motion
ALARM
(Red)
MW
(Yellow)
PIR
(Green)
ALARM
(Red)
MW
(Yellow)
PIR
(Green)
(Pattern disappears) (Pattern disappears) RATIO
IMBALANCE
MW environmental problem
MW unstable
MW range too long
PIR was blocked
(Pattern disappears) (Pattern disappears) RATIO
IMBALANCE
PIR range too short
PIR aimed wrong
PIR not reporting
(Pattern disappears) (Pattern disappears) RATIO
IMBALANCE
PIR environmental problem
PIR unstable
MW range too short
MW range too short
MW not reporting

TEST DESCRIPTION ALARM
(Red)
MW
(Yellow)
PIR
(Green)
ACTION
Microwave Pulse Self-Test Send the unit in for repair.¹
Temperature Compensation
Self-Test
Send the unit in for repair.¹

¹ Return the DT-6360STC to Honeywell for repair.