Installation Guide for DT7500SN V-Plex™ DUAL TEC

Installation Guide for DT7500SN V-Plex™ DUAL TEC

Brand: Honeywell

Category: Security System

Document Type: Installation Guide

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 7:18 p.m.

Warranty Information

Contact local Honeywell representative for product warranty information.

This document provides installation instructions for the Honeywell DT7500SN V-Plex™ DUAL TEC Motion Sensor. It covers mounting, wiring, component identification, setting selection (including sensitivity, pulse count, and anti-mask), walk testing, and troubleshooting. The manual details different lens options, pet immunity settings, and specific programming procedures for V-Plex™ panels. It also includes detection patterns and accessory information.

Troubleshooting and error codes

Condition Indicator LED
Power Up Slow Blinking Red (will finish within 60 seconds)
Normal Walk Test Red ON for 3 seconds if Alarm
Microwave Walk Test Yellow ON for 2 seconds if Microwave event detected
PIR event detected Green ON for 2 seconds if PIR event detected
Microwave Walk Test Red ON if Microwave is set too high
Green ON if Microwave is set correctly
OFF if Microwave is set too low
Trouble or Anti-Mask Fast Blinking Red (LED Enabled or Disabled)