Manual for DE 110S, DE 110, DE 120

Manual for DE 110S, DE 110, DE 120

Brand: Husqvarna

Category: Dust Extractor

Document Type: Manual

Language: EN

Uploaded: Nov. 21, 2025, 8:24 p.m.

Manual Publish Date: 2022-01-24

Warranty Information

Refer to the manufacturer or dealer for specific warranty details.

Getting Started:

  • Read the operator's manual and understand the instructions.
  • Perform daily maintenance.
  • Ensure the work area is clean and bright.
  • Use personal protective equipment.
  • Install the product correctly.
  • Verify power supply voltage and frequency match the type plate.
  • Connect the product cord with the extension cable to ensure they stay connected.

Attaching the Dust Extraction Hose:

  • Open the hose connector.
  • Insert the hose adapter and push until it clicks.
  • Push the hose lock button and pull the dust extraction hose.

Starting and Stopping:

  • Wait 5 seconds after starting for full suction.
  • Ensure the On/Off switch is set to '0'.
  • Connect to a power socket.
  • Push the appropriate start button ('I' or 'A' for auto-start).
  • To stop, set the switch to '0' or push the On/Off button.
  • Disconnect from the power socket.

Troubleshooting and error codes

Problem Cause Solution
The motor stops immediately after start or does not start. There is no power. Connect the product to a power supply.
The power cord is defective. Let an approved service agent repair the product.
There is a short circuit in the product. Let an approved service agent repair the product.
The HEPA filter is damaged or not installed (DE 110/DE 120). Replace or install the HEPA filter.
Too high voltage in power supply. Make sure that correct power supply is used.
The motor is on but there is no suction. The dust extraction hose is not connected correctly. Connect the dust extraction hose.
The dust extraction hose is blocked. Clean the dust extraction hose.
There is no Longopac bag. Install a Longopac cassette.
The Longopac is not closed down with a cable tie. Attach a cable tie.
Too low voltage in power supply. Make sure that correct power supply is used.
There is a hole in the dust extraction hose. Replace the dust extraction hose.
The suction is not sufficient. The prefilter is clogged. Remove dust particles from the prefilter. Clean or replace it if it is necessary.
The HEPA filter is clogged. Replace the HEPA filter. Refer to To replace the HEPA filter on page 18.
The top cover is loose. Close the top cover fully.
The seals are broken. Replace the seals.
The filters are incorrectly installed or damaged. Install the filters correctly. Replace damaged filters.
N/A Let an approved service agent repair the product.
Unusual noise comes from the product. N/A Let an approved service agent repair the product.