Installation Guide for DT-600

Installation Guide for DT-600

Brand: IntelliSense

Category: Security System

Document Type: Installation Guide

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 6:40 p.m.

Warranty Information

Refer to the warranty information provided with the IntelliSense product for details.

WIRING: Observe polarity. Use 14-22 AWG wire. Push excess wire back into the wall. Reverse polarity will not damage the unit. Refer to wiring diagram (Figure 2) for connections.
MOUNTING LOCATION: Select location for both technologies, aim sensor towards interior, away from heat/cooling sources and moving machinery. Max range at 2.3m (7'6") height. Ensure clear line-of-sight. Use 1.2m (4ft) height for Pet-Alley lens.
MOUNTING PROCEDURE: Use screwdriver to push latch to separate housing. Lift PCB latch to remove PCB, gently pull by microwave antenna. Secure rear housing with keyholes or breakout tabs. Seal knockouts to prevent insect entry.
SYSTEM TESTING: Apply power. Minimize motion until self-test (1 min) completes. Walk-test after LEDs extinguish. Walk across protected area; 2-4 steps should light LEDs. No motion should have all LEDs off.

Troubleshooting and error codes

Table 1 Self-Test Troubleshooting Matrix
TEST DESCRIPTIONALARM (Red)MW (Yellow)PIR (Green)ACTION
Power Up Self-Test (1 minute)No action required.
On Line - All Self-Tests Passed, Ready for Walk-TestSensor is working properly.
On-going Self-TestSend the sensor in for repair.1

1 Return the DT-600 to IntelliSense for repair.

Table 2 INFORMER Troubleshooting Matrix
Condition of LEDs with No MotionReaction of LEDs to Walk-TestType of ProblemPossible Causes
ALARM (Red)MW (Yellow)PIR (Green)ALARM (Red)MW (Yellow)PIR (Green)
RATIO IMBALANCEMW environmental problem
MW unstable
MW range too long
PIR was blocked
RATIO IMBALANCEPIR environmental problem
PIR unstable
MW range too short
PIR aimed wrong
PIR not reporting
RATIO IMBALANCEMW range too short
MW not reporting

NOTE: If you enter the detection pattern and the LEDs go off, you can retrieve the LED pattern to pinpoint the problem. Refer to the Trouble Memory section below.

Table 3 Trouble Output Troubleshooting Matrix
TEST DESCRIPTIONALARM (Red)MW (Yellow)PIR (Green)ACTION
Microwave Pulse Self-TestSend the sensor in for repair.1
Temperature Compensation Self-TestSend the sensor in for repair.1

1 Return the DT-600 to IntelliSense for repair.

LED Legend: = LED is Flashing Fast = LED is Flashing Slow = LED is ON = LED is OFF

Privacy Policy