Manual for K 7.20 MX

Manual for K 7.20 MX

Brand: KÄRCHER

Category: Pressure Washer

Document Type: Manual

Language: EN

Available Languages: EN , ES

Uploaded: April 20, 2026, 8:09 p.m.

Warranty Information

In each country, the guarantee conditions issued by the responsible sales company are applicable.

Preparing the unit:

  • Insert the power plug into the socket.
  • Turn the master switch to "I".

Switching on:

  • Press the safety button on the handgun and pull the lever.

Switching off:

  • Release the lever.
  • During breaks and when leaving the unit, secure it against inadvertent switching on by pressing the safety button.

Regulating pressure/flow rate:

  • To increase pressure, twist the spray lance to "+".
  • To reduce pressure, twist the spray lance to "-".

Adding cleaning agent:

  • Fill the detergent reservoir with detergent tablet and water, or concentrate and water. Observe dosage recommendations.
  • Meter cleaning agent using the valve: center-position for medium, "+" for large, "-" for small quantities.
  • Twist spray lance to "-" to the stop.

Recommended cleaning method:

  1. Spray cleaning agent sparingly on the dry surface and let it react (do not let it dry).
  2. Rinse off loosened dirt with the high-pressure jet.

Finishing operations:

  • Switch master switch to "0".
  • Pull out the power plug.

Troubleshooting and error codes

Fault Cause Remedy
Unit does not run Power supply interrupted Draw out power plug! Check power cord, power plug, extension cable and cable connections for damage.
Unit does not come up to pressure Spray lance set to "-" Set spray lance to "+".
In suction operation – unit not vented Vent unit, see "Operation".
Strainer in water inlet blocked Clean strainer, see "Care and Maintenance".
Water supply quantity too low Check the water supply to the water inlet of the unit for leaks and throughput.
Strong pressure fluctuations High-pressure nozzle in spray lance blocked Take off the spray lance, clean the hole in the high-pressure nozzle with a needle and rinse through with water again.
Water comes out of the housing underside Pump leaking 3 drops per minute are acceptable. For greater leakages contact the customer service.
Cleaning agent is not drawn in Spray lance set to "+" Set spray lance to "-".
Cleaning agent valve in the cleaning agent suction hose blocked Clean cleaning agent metering valve, see "Care and Maintenance".