| Problem | Possible Cause | Solutions |
| Air conditioner does not start. | The air conditioner is unplugged. | Make sure the air conditioner plug is pushed completely into the outlet. |
| The fuse is blown/circuit breaker is tripped. | Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. | |
| Power failure. | If power failure occurs, turn the mode control to off. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload. | |
| The current interrupter device is tripped. | Press the RESET button located on the power cord plug. If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. | |
| Air conditioner does not cool as it should. | FL appears in the display. | The water collection tank is full. Drain the tank and reset your settings. |
| Mode switched from Cool to Heat or vice versa. | To protect the compressor, the fan and compressor will momentarily stop if you switch modes from Cool to Heat or vice versa. After a few minutes, the product will resume operating in the new mode. | |
| Airflow is restricted. | Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner. | |
| The temp control may not be set correctly. | Set the desired temperature to a level lower than the current temperature. | |
| The air filter is dirty. | Clean the filter at least every 2 weeks. See the 'MAINTENANCE' section. | |
| The room may have been hot. | When the air conditioner is first turned on, you need to allow time for the room to cool down. | |
| Air conditioner freezes up. | Cooling coils have iced up. | See 'Air conditioner freezing up' below. |
| Se acumula agua en la bandeja base. | La humedad eliminada del aire se acumula en la bandeja base. | This is normal during brief periods in low humidity zones; it is normal during longer periods in very humid zones. |
| The air conditioner turns on and off rapidly. | Dirty air filter: limited air. | Clean the air filter. |
| Exterior temperature extremely high. | Consult installation instructions or installer. | |
| There is noise when the unit is cooling. | Air movement sound. | This is normal. If it is too high, adjust the fan speed to low. |
| The remote sensor deactivates prematurely. | The remote control has no coverage. | Use the remote control at a maximum distance of 20 feet (6.096 m) and within a 120° radius of the front of the unit. |
| Obstruction of the remote control signal. | Eliminate the obstruction. | |
| The room is too cold. | The set temperature is too low. | Increase the set temperature. |