| Error Code | Possible Causes | Solutions |
|---|---|---|
| tE1 or tE2 | • Temperature sensor failure | • Turn off the dryer and call for service. |
| HS | • Humidity Sensor failure. | • Turn off the dryer and call for service. |
| PSor PFor nP | • Electric dryer power cord is not connected correctly, or house power supply is incorrect. • House fuse is blown, circuit breaker sa tripped, or power outage has occurred. |
• Check the power supply or the connection of power cord to the terminal block. Refer to the Connecting electric dryers section of this manual for complete instructions. • Reset circuit breaker or replace fuse. Do not increase the fuse capacity if the problem is a circuit overload; have it corrected by a qualified electrician. |
| The dsplay shows "d90", "d95" | • The duct work is about 90%-95% blocked. ("d90" or "d95" error code displayed 2 hours only) • House exhaust system blocked. |
• Do not use the dryer until the exhaust system has been cleaned and/or repaired. Using the dryer with a severely restricted exhaust is dangerous and could result in a fire or other property damage. • Check the outside dryer vent while the dryer is operating to make sure there is strong airflow. • If the exhaust system is extremely long, have it repaired or rerouted. • Keep the area around the dryer clean and free of clutter. • Check the vent hood for damage or lint clogging. • Make sure the area around the vent hood is clear. • Install a shorter or straighter duct run. See the Instructions. |
| FLOW SENSE indicator shows four bars during the drying cycle or the display shows "d80" after drying. | • Ductwork is too long or has too many turns/restrictions. • Significant blockage of the ductwork due to lint buildup or debris. • The appliance has detected a restriction in the external dryer venting. |
• Ductwork should be checked/cleaned soon. Dryer can be used in this condition, but drying times may be longer. • If exhaust restrictions are sensed by the FLOW SENSE system, the indicator will remain on for two hours after the end of the cycle. Opening the door or pressing the POWER button will turn off the display. |