Brand: Logia
Category: Weather Station
Document Type: Manual
Language: EN
Available Languages: EN , ES
Brand: Logia
Category: Weather Station
Document Type: Manual
Language: EN
Available Languages: EN , ES
Uploaded: April 20, 2026, 8:06 p.m.
This product comes with a limited one-year warranty against defects in materials and workmanship.
| PROBLEM | SOLUTION |
|---|---|
| 7-in-1 wireless sensor is not connecting. | 1. Make sure the sensor is within the transmission range. 2. If it still does not work, reset the sensor, and resynchronize with console. |
| Additional wireless sensor(s) are not connecting. | 1. Make sure the sensor(s) is/are within the transmission range. 2. Make sure the channel displayed matches the channel selection on sensor. 3. If it still does not work, reset the sensor and resynchronize with console. |
| No Wi-fi connection | 1. Check the WI-FI icon on the display, it should be on if connectivity is successful. 2. In the console SETUP page, make sure the WI-FI settings (router's name, security type and password) are correct. 3. Make sure you connect to 2.4G band of the WI-FI router (5G not supported). |
| Data isn't transferring to ProWeatherLive. | 1. In the console SETUP page, ensure your Station ID and Station Key are correct. 2. In the "Edit Devices" of the console on PWL, ensure the device's Mac address is entered correctly. |
| Multi-day forecast, cloud cover, visibility, sunrise/sunset, moon rise/moon set times are not accurate. | 1. Ensure your console is connected to PWL. 2. Ensure latitude, longitude & time zone in "Edit Devices" of the console on PWL are correct. 3. Press the REFRESH button to update the data instantly. |
| Sunrise/sunset, moon rise/moon set times are different to that of PWL. | 1. Ensure your console is connected to PWL. 2. Ensure the console Time Sync is set to ON. |
| Rainfall data is not correct. | 1. Make sure the rain collector is clean for the tipping bucket to tip smoothly. 2. Make sure the sensor has stable and level to ensure correct tipping. |
| Temperature is too high in the daytime. | 1. Place the sensor in open area and at least 4.9′ (1.5 m) off the ground. 2. Ensure that the sensor is placed away from heat generating sources or structures, such as buildings, pavement, walls, or air conditioning units. |
| Some condensation beneath the UV sensor may occur overnight. | This will disappear when temperature rises up under the sun and will not affect the performance of the unit. |