| Operation lamp | Timer lamp | Failure phenomenon |
| ☆ | X | Indoor fan speed has been out of control for over 1 minute |
| ☆ | On | Indoor room temp. or evaporator sensor is open circuit or short circuit |
| On | ☆ | EEROM error |
| ☆ | ☆ | No over-zero signal |
| Failure phenomenon | Operation lamp | Timer lamp |
| Indoor fan speed has been out of control for over 1 minute | X | X |
| Indoor room temp. or evaporator sensor is open circuit or short circuit | ☆ | On |
| Failure phenomenon | Operation lamp | Timer lamp |
| Over current protection of the compressor occurs 4 times | X | ☆ |
| EEROM error | On | ☆ |
| No over-zero signal | ☆ | ☆ |
| Failure phenomenon | LED1 | LED2 | LED3 |
| Stand by | ☆ | ☆ | ☆ |
| High temp. protect of condenser | ☆ | ☆ | ☆ |
| Temp. sensor in condenser 1 is open circuit or short circuit | ☆ | ☆ | ☆ |
| Temp. sensor in condenser 2 is open circuit or short circuit | ☆ | ☆ | ☆ |