| Trouble | Remedy |
|---|---|
| No weld output; unit completely inoperative. | Place line disconnect switch in On position (see Sections 4-3 and 4-4). |
| Check and replace line fuse(s), if necessary, or reset circuit breaker (see Sections 4-3 and 4-4). | |
| Check for proper input power connections (see Sections 4-3 and 4-4). | |
| No weld output; meter display On. | Input voltage outside acceptable range of variation (see Section 4-5). |
| Check, repair, or replace remote control. | |
| Erratic or improper weld output. | Unit overheated. Allow unit to cool with fan On (see Section 3-3). |
| Use proper size and type of weld cable (see Section 4-6). | |
| Clean and tighten all weld connections. | |
| Check for correct polarity. | |
| No 115 volts ac output at optional duplex receptacle or Remote 14 receptacle. | Reset circuit breaker CB1 (see Section 4-8). |
| No 24 volts ac output at Remote 14 receptacle. | Reset circuit breaker CB2 (see Section 4-8). |