Motorola brand product is warranted for 2 years against defects in materials and workmanship under normal consumer usage.
If the product does not work properly, please contact your dealer or the nearest service center. Never attempt to disassemble the camera yourself. (We shall not be responsible for any problems caused by unauthorized repair or maintenance.)
Do not allow water or liquid intrusion into the camera.
In the use of the product, you must be strict compliance with the electrical safety regulations of the nation and region. When the product is mounted on wall or ceiling, the device shall be firmly fixed.
Do not use camera beyond specified voltage range.
Do not drop the camera or subject it to physical shock.
Avoid touching the camera lens.
If cleaning is necessary, please use clean cloth to wipe it gently.
Do not aim the camera at the sun or extra bright place.
Do not place the camera in extremely hot, cold (the operating temperature shall be -30°C~60°C), dusty or damp locations, and do not expose it to high electromagnetic radiation.
Camera
Quick start guide
4 tapping screws PA × 25
CD
Drill template
Plastic plug ×4
Rubber plug
Screwdriver
CVBS&DC IN cables
1 Ethernet Connector
2 Audio Input (MIC)
3 Audio Output (HP)
4 CVBS Video Output
5 Alarm Input/Output
6 DC12V Power Connector
7A Zoom-(only available for type A)
8A Zoom+(only available for typeA)
7B Focus
8B Zoom
9 Micro SD Card Slot
10 Reset
11 DC IN & CVBS Interface
* Please make sure that the wall or ceiling is strong enough to withstand 3 times the weight of the camera.
* Please install the camera in the dry environment. You'd better install back the lower dome less than 4 hours after removing it.
* Do not remove the protection film until finishing the installation.
① Rotate the trim ring anticlockwise to remove it from the camera.
②Attach the drill template to the place where you want to fix the camera and then drill 4 screw holes and 1 cable hole (if you want to route the cables through the ceiling) according to the drill template.
③ Loosen the screws to open the lower dome.
④ Route and connect these cables. Then secure the camera to the ceiling or wall with the screws provided.
⑤ Three-axis adjustment. Before adjustment, preview the image of the camera on a monitor (See Figure 5) and then adjust the camera according to the figure below to get an optimum angle.
* If the PoE switch is used to power the camera, DC12V power supply is not required.
* It is recommended to install the security cap for outdoor installation.
① Loosen the nut from the main element (security cap).
② Run the network cable (without RJ 45 connector) through the both elements. Then crimp the cable with RJ 45 connector.
③ Connect the cable to the hermetic connector. Then tighten the nut and the main cover.
There are two ways to access camera through LAN:
1. Access using IPTools App.
2. Access through browser, IE. (Explorer)
1. Make sure that the camera and the PC are well connected via LAN and in the same network.
2. Find the IP-Tool from the CD and then install it in the computer. After that, run the IP-Tool as shown in this section.
The default network settings are as shown below:
IP address: 192.168.226.201 HTTP:80
Subnet Mask: 255.255.255.0 Data Port: 9008
Gateway: 192.168.226.1
You may use the above default settings when you log in the camera for the first time.
1. Set the IP address of the PC and make sure the network segment should be as the same as the default settings of IP-CAM. Open the network and share center. Click "Local Area Connection" to pop up the following window. Select "Properties" and then select Internet protocol according to the actual situation (for example: IPv4). Next, click "Properties" button to set the network of the PC. Open the IE browser and input the default address of IP camera and confirm.
3. Modify the IP address. The default IP address of this camera is 192.168.226.201. Click the information of the camera listed in the above table to show the network information on the right hand. Modify the IP address and gateway of the camera and make sure its network address is in the same local network segment as that of the computer. Please modify the IP address of your device according to the practical situation.
For example, the IP address of your computer is 192.168.1.4. So the IP address of the camera shall be changed to 192.168.1.X. After modification, please input the password of the administrator and click "Modify" button to modify the setting.
The default password of the administrator is "123456".
4. Double-click the IP address and then the system will pop up the IE browser to connect IP-CAM. After downloading and running the Active X control, input the user name and password in the window to access.
6. Insert a micro SD card. After that, adjust Zoom or Focus to obtain an optimum image. Before adjustment, view the image of the camera on a monitor. For Type A, press the T or W button. For Type B, (a) push the IR light hood to the position as shown in Figure 6; (b) remove the lens cover; (c) adjust the Zoom and Focus; (d) install back the lens cover and move the IR light hood back.
Install the lower dome back to the camera and fix it with screws. Then put the trim ring onto the lower dome and then rotate it clockwise until it is locked. Finally, remove the protection film softly.