Warranty details are not explicitly stated in the provided sections.
Basic Operation:
| Error Code | Malfunction decision conditions | Supposed causes |
|---|---|---|
| P1 | An abnormal voltage rise or drop is detected by checking the specified voltage detection circuit. |
|
| P2 | If the sampling voltage is not 5V, the LED will display the failure. |
|
| P4 | An abnormal inverter compressor drive is detected by a special detection circuit, including communication signal detection, voltage detection, compressor rotation speed signal detection and so on. | Wiring mistake; IPM malfunction; Outdoor fan ass'y faulty; Compressor malfunction; Outdoor PCB faulty |