Cooling Mode: Cools the room and reduces humidity. Heating Mode: Heats the room. May enter a defrost cycle. Dry Mode: Reduces humidity. Fan-Only Mode: Provides ventilation without heating or cooling. Auto Mode: System determines configuration based on temperature. Display On/Off: Controls the front panel LED display. Sleep Mode: For periods of lower cooling needs, conserves energy. Fan Speed: Adjust between Auto, Low, Mid, and High. ECO Feature: Manages operation for energy saving. TURBO Option: Operates at highest fan speed for quick temperature adjustment. Timer ON/OFF: Sets automatic on/off delays. 46°F Freeze Protection: Maintains a minimum temperature of 46°F. MUTE Mode: Operates at lowest fan speed for minimal noise. I FEEL: Remote acts as a temperature sensor. SELF-CLEAN: Cleans the indoor evaporator.

Troubleshooting and error codes

MALFUNCTIONPOSSIBLE CAUSES
If the appliance does not operate or respond...There is a power failure/plug pulled out
The indoor/outdoor unit fan motor was damaged
There is a faulty compressor or thermomagnetic circuit breaker
There is a faulty protective device or fuses
The electrical connections are loose
The system has entered a protection mode
The system has entered an overvoltage or undervoltage protection
The TIMER-ON function is active
The electronic control board was damaged
If there are strange odors...The air filter is dirty
If there's running water...There was a backflow of liquid into the refrigerant circulation.
If a fine mist is coming from the air outlet...This occurs when the air in the room becomes very cold, for example in "COOLING" or "DEHUMIDIFICATION/DRY" modes
If strange noises are being emitted...This noise is made by the expansion or contraction of the front panel due to variations in temperature, and if so, is normal
If the airflow is insufficient, and the air is not hot or cold enough...The temperature setting is unsuitable
The air conditioner intakes and outlets may be obstructed
The air filter may be dirty
The fan speed may be set at the minimum
There may be too many other heat sources in the room
The system may be getting low on refrigerant, pressures should be checked
If the appliance does not respond to commands...The remote control may not be close enough to the indoor unit
The batteries of remote control may need to be replaced
There are obstacles between remote control and indoor unit signal receiver
If the display is off...The DISPLAY button has been pressed
Switch off the air conditioner immediately and cut off the power supply in the event of...There has been a power failure
Strange noises not due to expansion/contraction are heard during operation
The electronic control board is faulty or malfunctioning
Any fuses or switches are faulty or malfunctioning
The sound of spraying water or objects are heard inside the appliance
The cables or plugs have overheated
There are very strong odors being emitted from the appliance
ERROR SIGNALS ON THE DISPLAY
In case of error, the display on the indoor unit may show the following error codes:
DisplayDescription of the errorDisplayDescription of the trouble
E1Indoor temperature sensor faultE8Outdoor discharge temperature sensor fault
E2Indoor pipe temperature sensor faultE9Outdoor IPM module fault
E3Outdoor pipe temperature sensor faultEAOutdoor current detection fault
E4Refrigerant system leakage or faultEEOutdoor PCB EEPROM fault
E6Malfunction of indoor fan motorEFOutdoor fan motor fault
E7Outdoor air temperature sensor faultEHOutdoor suction temperature sensor fault