Manual for WYT

Manual for WYT

Brand: PIONEER

Category: Air Conditioner

Document Type: Manual

Language: EN

Available Languages: EN , ES

Uploaded: Nov. 21, 2025, 8:53 p.m.

Warranty Information

Refer to the warranty card for specific details.

Remote Controller Functions:

  • ON/OFF: Turns the unit on and off.
  • ECO: Adjusts temperature by 2°C in cooling (increases) or heating (decreases) mode.
  • MODE: Selects operation mode (Cooling, Dry, Fan, Heating).
  • FAN SPEED: Adjusts fan speed (Auto, Low, Mid, High).
  • SWING: Controls the movement of air deflectors.
  • HEALTH: Activates/deactivates ionizer or plasma generator (for inverter types).
  • TURBO: Maximum cooling (16°C) or heating (31°C) output.
  • DISPLAY: Turns the LED display on/off.
  • SLEEP: Activates sleep mode.
  • TIMER: Sets automatic on/off timer.
  • TEMP UP/DOWN: Increases/decreases temperature or time by 1 unit.

Note: Remote controller needs to be set for Cooling Only or Heat Pump operation.

Troubleshooting and error codes

Failure Type LED Code Digital LED Code
Indoor and outdoor communication fault RUN、TIMER-both winking E0
Outdoor communication failure RUN、TIMER-both winking EC
Indoor room temperature sensor (IRT) fault RUN-1 time/8s E1
Indoor coil temperature sensor (IPT) fault RUN-2 times/8s E2
Outdoor coil temperature sensor (OPT) RUN-3 times/8s E3
System abnormity RUN-4 times/8s E4
Model configuration wrong RUN-5 times/8s E5
Indoor fan motor fault RUN-6 times/8s E6
Outdoor temperature sensor RUN-7 times/8s E7
Exhaust temp. sensor RUN-8 times/8s E8
IPM drive and module fault RUN-9 times/8s E9
Outdoor fan motor fault (DC motor) RUN-10 times/8s EF
Current sensor fault RUN-11 times/8s EA
EEPROM fault RUN-12 times/8s EE
Temp. switch fault (on top of the compressor) RUN-13 times/8s EP
Voltage sensor fault RUN-14 times/8s EU
Air filter duty CL