| Failure | Possible Cause | Remedy |
|---|---|---|
| The air conditioner does not operate at all. |
1. Power outage. 2. Circuit breaker tripped. 3. Line voltage too low. 4. Remote control batteries are worn out. |
1. Restore power. 2. Contact an electrician or dealer. 3. Consult an electrician or dealer. 4. Replace batteries. |
| The operation lamp blinks and the air conditioner does not operate. | Problem with the unit. | Contact after-sales service. |
| The compressor starts but stops immediately. | Obstacle in front of the condenser coil. | Remove the obstruction. |
| Insufficient cooling (or heating). |
1. Dirty or blocked air filter. 2. Heat source or too many people in the room. 3. Doors and/or windows open. 4. Obstacle in front of air intake or outlet. 5. Thermostat set too high for cooling (or too low for heating). 6. (Outdoor temperature too low for heating.) |
1. Clean the air filter to improve air circulation. 2. If possible, eliminate the heat source. 3. Close them to prevent hot (or cold) air from entering. 4. Remove the obstacle to ensure good airflow. 5. Set the temperature lower (or higher). 6. (Consult the dealer or try using another heating appliance.) |
| The air conditioner produces a clicking sound. | Plastic parts expand or shrink due to a sudden temperature change during heating or cooling, causing a slight clicking sound. | This is normal and the sound will disappear after a short while. |
| The operation lamp lights up, but the outdoor unit does not operate. | 1. Using a mobile phone near the air conditioner may interfere with its normal operation. |
1. Cut power, then turn the air conditioner back on after a moment. 2. Contact the dealer. |