**IMPORTANT SAFETY INFORMATION:** Read all instructions before use. Use only qualified personnel for installation and servicing. Follow all electrical codes and warnings. **INSTALLATION PRECAUTIONS:** Ensure proper mounting, connect refrigerant tubing using the flare method, and insulate all tubing. Proper grounding and leakage breaker installation are crucial. For outdoor units, ensure a stable, level foundation, and anchor securely if in an area with high winds. In snowy areas, install on a raised platform and provide snow vents. **SERVICING:** Always turn off power at the main box before servicing. Keep fingers and clothing away from moving parts. Ventilate enclosed areas when working with refrigerant to avoid toxic gas formation. Use only tools specifically designed for R410A refrigerant. **REFRIGERANT HANDLING (R410A):** Pay special attention when servicing units with R410A. Use specific tools and follow procedures for charging and leak detection. Ensure correct connections to prevent refrigerant loss. **AIR PURGING:** Purge air and moisture completely from the refrigerant system using a vacuum pump and manifold valve to prevent system issues. Monitor vacuum pressure and check for leaks. **TEST RUN:** Conduct a test run using the remote controller to verify proper operation. Ensure the system shifts to cooling operation and cool air is felt. Reset the remote controller to normal mode after the test.

Troubleshooting and error codes

Trouble Possible Cause Remedy
Unit does not operate Power supply disconnected. Check the power supply cord and plug.
Remote controller batteries depleted. Replace the batteries.
Remote controller signal not received. Check for obstacles, distance, or interference.
Indoor fan does not rotate Fan motor failure. Check the fan motor.
Fan speed setting is too low. Increase fan speed.
Outdoor fan does not rotate Fan motor failure. Check the fan motor.
Cooling is not sufficient Dirty air filter. Clean or replace the air filter.
Room temperature too high. Allow the unit to operate for a longer period.
Incorrect refrigerant charge. Check and adjust refrigerant level.
Water leakage Drain hose clogged or kinked. Clear obstructions or kinks in the drain hose.
Excessive condensation. Ensure proper insulation of tubing.