Cooling & Electric Heating Models:
  • Cooling: Compressor cycles ON/OFF to maintain room temperature. A 3-minute delay prevents immediate restart after stopping. Compressor turns ON when room temp rises above set temp + 1°F, and OFF when it falls below set temp.
  • Heating: Heater cycles ON/OFF. Heater turns ON when room temp falls below set temp, and OFF when it rises above set temp + 1°F.
Heat Pump Models:
  • Cooling: Similar to Cooling & Electric Heating Models.
  • Heating (except during defrosting): Similar to Heating in Cooling & Electric Heating Models.
  • Changeover to Heater ON: Occurs when room temp falls below set temp - 4°F; unit switches from heat pump to electric heater.
  • Changeover to Heat Pump: Occurs when room temp rises above set temp - 3°F; unit resumes heat pump operation.
Freeze Prevention: Compressor stops if indoor heat exchanger coil temp drops below 32°F, and restarts above 50°F. Freeze Protection: Electric heater turns ON if room temp falls below 46.4°F, regardless of mode, to prevent freezing. Indoor fan speed synchronizes with heater operation. Defrosting Operation (Heat Pump): When outdoor coil temp is below 14°F, compressor turns OFF and electric heater turns ON. Defrosting ends when outdoor coil temp rises above 41°F. During defrosting, heat is provided by the electric heater. Fan Cycle Switch:
  • CYCLE: Indoor fan synchronizes with compressor/heater. Saves power.
  • CONT: Fan operates continuously, regardless of compressor/heater.

Troubleshooting and error codes

Trouble Cause Remedy
Air conditioner does not operate Power cord is not plugged in. Plug in the power cord.
Fuse is blown or circuit breaker is tripped. Check the fuse or circuit breaker. Replace if necessary.
Room temperature is set to OFF. Set the thermostat to COOL or HEAT.
Some part of air conditioner does not operate Filter is dirty. Clean the filter.
Thermostat is not set correctly. Adjust the thermostat setting.
Air conditioner operates, but abnormalities are observed Room temperature is not comfortable. Adjust the thermostat setting.
Air filter is dirty. Clean the air filter.
Outdoor unit is obstructed. Ensure adequate space around the outdoor unit.