Temperature Setting:
Key Lock Operation:
Alarm Temperature Setting:
Alarm Resume Time Setting:
Defrosting:
| Situation | Possible Cause | Solution |
|---|---|---|
| If nothing operates even when plug in | 1. The unit is not connected to the power supply or capacity of power source is not enough. | Check power connection and source. |
| 2. The power switch is not ON. | Turn the power switch ON. | |
| 3. There is a power failure, the fuse is blown, or the circuit breaker is activated. | Check for power failure, fuse, or circuit breaker. | |
| When the unit does not accept changes of set-point temperature | 1. The key lock is not "OFF". | Set key lock to OFF. |
| When alarm is activated (On start-up) | 1. The temperature in the unit does not match set value. | Allow unit to stabilize. |
| When alarm is activated (In use) | 1. The door was kept opened for long time. | Close the door. |
| 2. The set value was changed. | Reset the temperature. | |
| 3. The containers of high temperature (load) were put in the unit. | Allow unit to stabilize. | |
| When the unit does not get cold enough | 1. The air exhaust vent is blocked by refrigerator contents. | Ensure proper ventilation. |
| 2. A large amount of warm product was put in the unit. | Load items gradually. | |
| 3. There is any heat sources in the unit. | Remove heat sources. | |
| 4. The door is opened frequently. | Minimize door openings. | |
| 5. The ambient temperature is too high. | Ensure ambient temperature is within range. | |
| 6. The unit is in direct sunlight. | Relocate unit away from direct sunlight. | |
| 7. The door is not securely closed. | Ensure door is closed properly. | |
| 8. The door seal is damaged or foreign substance inserted between the door gaskets. | Clean or replace door seal. |