  • Cooling performance: Maintains chamber temperature at -30°C even with an ambient temperature of 35°C.
  • Environmentally conscious: Uses HFC refrigerant (R-134a) and CP urethane foaming for insulation.
  • Reliability: Features flash memory for various functions, battery age indication, adjustable temperature alarm delay, and a new door lock mechanism.
  • Control specifications: Microcomputer-based temperature control with a setting range of -18°C to -35°C. Includes high and low temperature alarms, power failure alarm, and self-diagnosis functions.
  • Key operations: SET for setting values, DEF for defrosting, ALARM TEST for alarm testing, and navigation keys for setting and function modes.
  • Error codes: E01 (sensor disconnected), E02 (sensor short-circuited), E09 (battery switch OFF).
  • Alarms: High/low temperature alarms, power failure alarm, with audible and visual indicators, and remote alarm activation.

Troubleshooting and error codes

Error code Description Action
E01 Temp. sensor is disconnected. Buzzer sounds and remote alarm activates. Compressor is turned on. Press BUZZER key to stop buzzer sounding. Remote alarm keeps activating.
E02 Temp. sensor is short circuited. Buzzer sounds and remote alarm activates. Compressor is turned on. Press BUZZER key to stop buzzer sounding. Remote alarm keeps activating.
E09 Battery switch is OFF When battery switch is off position or battery is unconnected, press ALARM key to display 'E09'.