Brand: SANYO
Category: Refrigerator
Document Type: Manual
Language: EN
Available Languages: EN , ES
Uploaded: Nov. 21, 2025, 7:17 p.m.
Contact Sanyo sales agency for battery replacement and recycling.
| Trouble | Cause | Remedy |
|---|---|---|
| No refrigeration | 1. Voltage too low. 2. Power not supplied. 3. Breaker tripped. |
1. Call electrician. 2. Check power supply. 3. Reset breaker. |
| Poor refrigeration | 1. High ambient temperature. 2. Door not shut tightly. 3. Inner lid not installed correctly. 4. Set temperature improper. 5. Grille blocked. 6. Filter clogged. 7. Direct sunlight. 8. Heating source nearby. 9. Access port cap/insulation not set. 10. Too many unfrozen articles. |
1. Ensure proper environmental temp. 2. Close door tightly. 3. Install inner lid correctly. 4. Set temperature properly. 5. Clear grille. 6. Clean filter. 7. Move from direct sunlight. 8. Move heating source away. 9. Set cap/insulation correctly. 10. Load fewer articles. |
| Noise | 1. Freezer unstable. 2. Not leveled. 3. Touching something. 4. First operation after shutdown. |
1. Stabilize unit. 2. Level unit. 3. Move obstructing object. 4. Noise may cease as temperature lowers. |
| Alarm test key fails | 1. Battery discharged. | 1. Operate freezer for 3 hrs, then test. Fully discharged battery needs 2 days operation. |
| Recorder not operating | 1. Chart not fed. 2. Temp not recorded. |
1. Check dry cell (lasts ~1 yr). 2. Check pen and chart setting. |