Warranty Information

Sanyo Fisher Company warrants this product against defects for 1 year labor and parts, and 5 years on the compressor.

Temperature Control: Adjust the cold control knob. Turning clockwise towards 'MAX' lowers the temperature. Temperature varies with food quantity and door openings. Use 'MAX' for quick ice cube needs. Frequent cycling is normal due to compactness.

Defrosting: Defrost when ice layer reaches 1/4 inch thick. Remove food and ice trays, place drip tray. Set cold control to 'OFF' to start. Defrosting takes hours; speed up by removing food, opening door, or using warm water on frost. Never use sharp instruments or boiling water. After defrosting, empty drip tray, set cold control to desired position between 'MIN' and 'MAX'. To suspend, return to operating position.

Ice Removal: Twist flexible ice cube trays to remove ice. Do not use boiling water or metal instruments which can damage parts.

Troubleshooting and error codes

Problem Possible Cause Solution
Refrigerator not starting Not plugged in. Plug into a grounded outlet.
Cold control set to OFF. Set cold control to desired position.
Thermostat Control Device (PTC) delay. Wait 3 minutes before restarting.
Motor running constantly Cold control set to MAX. Adjust to a less cold setting.
Door open too long. Close door properly.
Too much food recently added. Allow time for cooling.
Excessive frost build-up Door not sealing properly. Check door gasket for obstructions or damage.
Cold control set too low. Adjust to a warmer setting.
Interior too warm Cold control set too high (too cold). Adjust to a warmer setting.
Door opened too frequently. Reduce frequency of door openings.
Too much food recently added. Allow time for cooling.
Ice cubes are too small Cold control set too high (too cold). Adjust to a colder setting (MAX).
Water leakage Drip tray full or blocked. Empty and clean drip tray.
Defrosting process incomplete. Allow complete defrost cycle.