Warranty Information

Guarantee is 12 months from purchase date, proof of which will be required for any claim.

  • Operation: Control unit functions via the control panel or remote. Modes include Cooling, Fan, Heating, and Dehumidifier. Adjust fan speed, set timer, and activate sleep mode or oscillation. Maximum cooling can be activated.
  • Self-Protection: Features include freezing protection (displays 'E4'), full water tank alert (displays 'P2'), compressor delay, and low refrigerant warning (displays 'E3').
  • Water Drainage: Under normal use, condensate is evaporated. If the water tank is full, drain it manually by removing the drain plug and cap.
  • Maintenance: Turn unit OFF and disconnect from mains before cleaning. Clean air filters every two weeks. If unit is not used for a long period, drain water tank and store in a safe, dry area.

Troubleshooting and error codes

Error Code Description Remedy
E4 Freezing Protection When the temperature rises, the previous setting is resumed.
P2 Full Water Tank Drain the tank (see section 5.4 for remedy).
E3 Low Refrigerant Shut the compressor and water pump down and the fan speed will drop to minimum setting.