Guarantee is 12 months from purchase date, proof of which is required for any claim.
This is a 3-in-1 portable air conditioner, air cooler, and dehumidifier. It features thermostatic control, a 24-hour timer, and sleep mode. The self-evaporating system enhances efficiency. It offers Cooling, Dehumidifying, and Fan modes. The unit can be controlled via a soft-touch panel or remote control. Ensure proper installation with the exhaust hose vented outside. Manual drainage or continuous drainage options are available. The unit has safety features like overload protection and automatic defrost.
| SYMPTOM | POSSIBLE CAUSE | REMEDY |
|---|---|---|
| The unit is not working | No power | Connect to power source and turn the unit ON |
| Full water indicator is illuminated | Drain the water | |
| The unit works with reduced capacity | Low room temperature | Change the set temperature |
| Dirty air filter | Clean the air filter as required | |
| Air ducts are blocked | Clear obstacles. Re-position unit into clear space | |
| Doors or windows open | Close the doors and windows | |
| Incorrect mode and temperature selected | Select correct mode and temperature to suit desired application | |
| Detached exhaust hose | Securely reattach exhaust hose | |
| Water leakage | Spillage when moving the unit | Empty the water tank before moving the unit |
| The drain hose is kinked or bent | Straighten the drain hose | |
| Excessive noise | The unit is on an uneven surface | Place the unit onto a flat horizontal surface |
| Loose, vibrating parts | Check for loose parts and re-tighten | |
| Water flowing sound | Normal sound of refrigerant flowing | |
| Error codes | E0 Communication faults between main PCB and display PCB | Contact Sealey service centre |
| E1 Ambient temperature sensor fail | Contact Sealey service centre | |
| E2 Coil temperate sensor failures | Contact Sealey service centre | |
| Ft Condensate water high level alarm | Drain the water |