Manual for SAC9002

Manual for SAC9002

Brand: SEALEY

Category: Air Conditioner

Document Type: Manual

Language: EN

Uploaded: Nov. 21, 2025, 8:10 p.m.

Manual Publish Date: 2022-01-24

Warranty Information

Guarantee is 12 months from purchase date, proof of which is required for any claim.

START UP AND SHUTDOWN: Press POWER to turn the unit ON or OFF.

OPERATION MODES: Select COOL to lower temperature, FAN to circulate air, or DRY for dehumidifying. SLEEP mode activates only via remote and is available in COOL mode.

COOLING: Select COOL mode, adjust temperature (16°C-32°C) using UP/DOWN buttons, and set fan speed (HIGH/LOW). Airflow direction is adjusted via louvres.

VENTILATE: Select FAN mode and desired fan speed. Air is circulated but not cooled.

DRYING: Select DRY mode, connect drain hose. Fan speed is fixed at low.

TIMER: Set the unit to START or STOP automatically (1-24 hours) using the TIMER button and UP/DOWN controls.

AUTO DEFROST: Unit automatically defrosts at low temperatures. POWER indicator blinks during defrost.

OVERLOAD PROTECTION: A three-minute delay prevents compressor restart after power loss.

MANUAL DRAINAGE: Switch off, unplug, move to a suitable location, remove drain plug to empty water tank. Replace plug securely.

CONTINUOUS DRAINAGE: Connect drain hose to water outlet and route to a container or drain. Ensure hose is straight and angled downwards.

Troubleshooting and error codes

SYMPTOM POSSIBLE CAUSE REMEDY
The unit is not working No power Connect to power source and turn the unit ON
Full water indicator is illuminated Drain the water
The unit works with reduced capacity Low room temperature Change the set temperature
Dirty air filter Clean the air filter as required
Air ducts are blocked Clear obstacles. Re-position unit into clear space
Doors or windows open Close the doors and windows
Incorrect mode and temperature selected Select correct mode and temperature to suit desired application
Detached exhaust hose Securely reattach exhaust hose
Water leakage Spillage when moving the unit Empty the water tank before moving the unit
The drain hose is kinked or bent Straighten the drain hose
Excessive noise The unit is on an uneven surface Place the unit onto a flat horizontal surface
Loose, vibrating parts Check for loose parts and re-tighten
Water flowing sound Normal sound of refrigerant flowing
Error codes E0 Communication faults between main PCB and display PCB Contact Sealey service centre
E1 Ambient temperature sensor fail Contact Sealey service centre
E2 Coil temperate sensor failures Contact Sealey service centre
Ft Condensate water high level alarm Drain the water